A fix is available
APAR status
Closed as program error.
Error description
Output from VMCONIO class is not being directed as specified with PRECEDENCE STARMSG.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users with virtual machines that have * * both an IUCV *MSG or *MSGALL conection and a * * secondary user * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** If a virtual machine with an IUCV connection to *MSG or *MSGALL has an active secondary user and has SET VMCONIO IUCV, virtual machine console output will be sent to the secondary user rather than to the IUCV connection. APAR VM65715 added the TERMINAL command PRECEDENCE option to allow this behavior to be changed, such that TERMINAL PRECEDENCE STARMSG would send console output to the guest via IUCV. However, this change only affected the behavior of CP output.
Problem conclusion
Code was changed to honor the TERMINAL PRECEDENCE setting for guest console output, sending it via the IUCV connection if TERMINAL PRECEDENCE STARMSG is in effect.
Temporary fix
Comments
APAR Information
APAR number
VM66287
Reported component name
VM CP
Reported component ID
568411202
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-10
Closed date
2019-12-09
Last modified date
2021-06-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UM35571
Modules/Macros
HCPRVC
Fix information
Fixed component name
VM CP
Fixed component ID
568411202
Applicable component levels
R710 PSY UM35571
UP19/12/18 P 2101
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG27M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"710","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]
Document Information
Modified date: