IBM Support

PQ97677: THIS APAR PROVIDES STACK CAPABILITY FOR SECONDARY IC AND ALSO INCLUDES LBI SUPPORT FOR RECOVERY FUNCTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This APAR provides following items:
    - STACK capability for secondary IC
      - LBI tape support for Recovery function
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy          *
    *                 for z/OS version 3 users (FMID=H1J0310)      *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR improves HPIC stack option:   *
    *                      - Defferent ddname of secondary IC to   *
    *                        the same ddname of primary IC can be  *
    *                        used in the Image Copy function.      *
    *                      - The specification order of ddname can *
    *                        be changed in the Create Image Copy   *
    *                        function.                             *
    *                                                              *
    *                      This APAR also fixes following          *
    *                      problems:                               *
    *                      - In the Create Image Copy function,    *
    *                        and the Recovery function, HPIC       *
    *                        abends S013 ( ABEND013 ) when the     *
    *                        record format of input image copy     *
    *                        data set is LBI.                      *
    *                      - In the Create Image Copy function,    *
    *                        HPIC abends S0C1 ( ABEND0C1 ) when    *
    *                        ICERPRT DD is not specified in the    *
    *                        JCL.                                  *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR provides following enhancements for HPIC stack option:
    - Different ddname of secondary IC to the same ddname of primary
      IC can be used in the Image Copy function.
    - The specification order of ddname can be changed in the Create
      Image Copy function.
    
    This APAR fixes following problem:
    - In the Create Image Copy function, and the Recovery function,
      HPIC abends S013 ( ABEND013 ) when the record format of input
      image copy data set is LBI.
    - In the Create Image Copy function, HPIC abends S0C1
      ( ABEND0C1 ) when ICERPRT DD is not specified in the JCL.
    

Problem conclusion

Temporary fix

Comments

  • The module FABJICDD has been modified to remove the logic that
    checks the ddname of secondary IC, and specification order of
    ddname for the stack output data set.
    
    The module FABJRDB9, FABJCRC1 have been modified to bypass the
    logic that issues BUILDRCD macro for LBI format data set of the
    input image copy data set.
    
    The module FABJCRC0, FABJCRC1 have been modified to bypass the
    logic that calls FABJRPT0 when ICERPRT DD is not specified in
    the JCL.
    
    The module FABJMSGC has been modified to collect the message
    text of FABJ3932E ( MSGFABJ3932E ).
    
    << Documentation Change >>
    
    IMS High Performance Image Copy for z/OS Version 3 Release 1s
    User's Guide SC18-7617-00 ( SC18761700 ) should be changed
    as follows:
    ==============================================================
    
    2.0 Operating Instructions
     2.2 JCL Requirements
      2.2.1 FABJMAIN JCL
    
     +-----------------------------------------------------------+
     | Table 6. DD statements for the Create Image Copy function |
     | of the FABJMAIN JCL                                       |
     +-----------+---------+-----------+-------------------------+
     | DDNAME    |  Use    |  Format   |  Required or Optional   |
     +-----------+---------+-----------+-------------------------+
    ||ICERPRT    |Output   |LRECL=133  |Optional                 |
     +-----------+---------+-----------+-------------------------+
     |ICEDLIST   |Output   |LRECL=133  |Optional                 |
     +-----------+---------+-----------+-------------------------+
    
    2.0 Operating Instructions
     2.2 JCL Requirements
      2.2.1 FABJMAIN JCL
       2.2.1.3 Function-Unique DD Statement for HPIC Create Image
               Copy Function
    
     ICERPRT DD
    |This statement specifies the optional output message data set.
     This data set contains the Create Image Copy report. It can
     reside on a tape, a direct-access volume, or a printer, or it
     can be routed through the output stream (SYSOUT).
    

APAR Information

  • APAR number

    PQ97677

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2004-11-26

  • Closed date

    2004-12-08

  • Last modified date

    2005-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ95850

Modules/Macros

  •    FABJCRC0 FABJCRC1 FABJICDD FABJMSGC FABJRDB9
    

Publications Referenced
SC18761700    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R310 PSY UQ95850

       UP04/12/09 P F412

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89E","label":"IMS HP Image Copy"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]

Document Information

Modified date:
14 December 2020