IBM Support

PQ97488: CCF RETURNS A CCF0488I WITH A RC=0 BEFORE THE DB IS ACTUALLY CLOSED WHEN USING THE CCF REMOTE STC TO ISSUE DBR COMMANDS.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CHANGED CCF TO PERFORM ADDITIONAL DATA BASE STATUS CHECKING
    WHEN /DBR COMMANDS ARE ENTERED.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS CCF.                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: CCF returns a CCF0488I with a RC=0.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    CCF returns a CCF0488I with a rc=0 before the DB is actually
    closed when using the CCF REMOTE STC to issue DBR commands.
    

Problem conclusion

  • CCF has been changed to verify the data base is closed prior
    to returning the CCF0488I message.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ97488

  • Reported component name

    IMS COMMAND CTL

  • Reported component ID

    5655F4000

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2004-11-22

  • Closed date

    2005-01-12

  • Last modified date

    2005-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ96777

Modules/Macros

  •    CCFDB510 CCFDB610 CCFDB710 CCFDB810 CCFDB910
    

Fix information

  • Fixed component name

    IMS COMMAND CTL

  • Fixed component ID

    5655F4000

Applicable component levels

  • R110 PSY UQ96777

       UP05/01/14 P F501

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY6","label":"IMS Command Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]

Document Information

Modified date: