IBM Support

PQ96271: SMS KEYWORDS SPECIFIED IN GLOBAL STATEMENT ARE NOT EFFECTIVE WHEN USING STACKING FUNCTION.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The following keywords regarding SMS classes are not effective
    when using the STACKING function even though they are specified
    in the GLOBAL statement:
    
         DATACLAS
         MGMTCLAS
         STORCLAS
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy          *
    *                 for z/OS version 3 users (FMID=H1J0310)      *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPIC ignores SMS related keywords       *
    *                      specified in the GLOBAL statement       *
    *                      when stacking is used.                  *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR provides the fix for following problem:
    HPIC ignores the following keywords specified in the GLOBAL
    statement when stacking is used:
       DATACLAS
       MGMTCLAS
       STORCLAS
    

Problem conclusion

  • FABJICDD has been modified to set DATACLAS, MGMTCLAS, and
    STORCLAS keywords as allocation information of stacking output
    image copy data sets if they are specified in the GLOBAL
    statement.
    
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    IMS High Performance Image Copy for z/OS Version 3 Release 1
    User's Guide SC18-7617-00 ( SC18761700 ) should be changed
    as follows:
    
    
    6.2.4 Dynamic Allocation for the Stacked Data Set
    
      When stacking is used, the Image Copy function always
      dynamically allocates the stacked image copy data sets. The
      Image Copy function uses the allocation information inherited
      from the stacked data set. The data set name for each stacked
      image copy data set is constructed as follows:
    
         ichlq.ICn.dbdname.ddname.Dyyddd.Thhmmss
    
      where:
    
      ichlq
         is specified with the ICHLQ= keyword.
      n
         is 1 or 2 indicating the primary or secondary copy.
      dbdname
         is the DBD name or the partition dbdname of the database
         to be copied.
      ddname
    |    is the DD name specified in the STACK keyword.
      yyddd
         is the date.
      hhmmss
         is the time stamp.
    
    
      When the stacked data set is requested, HPIC dynamically
      allocates a dummy data set first. The dummy data set is not a
      real data set, but its allocation information is used
      internally for control. If you control the data set name by
      using the tape control program, you need to take the dummy
      data set into consideration. The dummy data set name is:
    
         DSN=ichlq.ddname.job_no.Thhmmss
    
      where:
    
      ichlq
         is the data set name prefix specified with the ICHLQ=
         keyword.
      ddname
         is the ddname specified in the STACK keyword.
      job_no
         is the job number of the HPIC execution job.
      hhmmss
         is the time stamp.
    
    
      Note: You can change the data set naming convention by the
            data set naming template.
    
    
    | When the stacking is used and DD card for stacked data set is
    | not presented in running JCL, the Image Copy function
    | dynamically allocates the stacked data set by using the
    | allocation information specified by the ICEIN control
    | statements.
    | The following keywords are effective for each stacked image
    | copy data set only when they are specified in the GLOBAL
    | statement. If they are specified in any other statement except
    | the GLOBAL statement, they are ignored.
    
         UNIT=icunit
    
      where:
    
      icunit
         is the unit name specified by the ICEIN UNIT keyword.
    
    
         VOL=(,,,volcnt,SER=(ser1,ser2,...))
    
      where:
    
      volcnt
         is the volume count specified by the ICEIN VOLCNT keyword.
      ser1, ser2 ...
         are the volume serial numbers specified by the ICEIN
         VOLSER keyword.
    
    
         EXPDT=expdt or RETPD=retpd
    
      where:
    
      expdt
         is the expiration date specified by the ICEIN EXPDT
         keyword.
      retpd
         is the retention period specified by the ICEIN RETPD
         keyword.
    
    
    |    DATACLAS=data-class-name
    |
    | where:
    |
    | data-class-name
    |    is the name of the data class specified by the ICEIN
    |    DATACLAS keyword.
    |
    |
    |    MGMTCLAS=management-class-name
    |
    | where:
    |
    | management-class-name
    |    is the name of the management class specified by the ICEIN
    |    MGMTCLAS keyword.
    |
    |
    |    STORCLAS=storage-class-name
    |
    | where:
    |
    | storage-class-name
    |    is the name of the storage class specified by the ICEIN
    |    STORCLAS keyword.
    
    
      The Image Copy function uses the volume information of the
      dynamically allocated stacked data set when allocating
      subsequent stacked image copy data sets.
    
    | Note: The disposition parameter for each stacked image copy
    |       data set is as follows:
    | DISP=(NEW,KEEP)
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ96271

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2004-10-26

  • Closed date

    2004-12-02

  • Last modified date

    2005-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ95682

Modules/Macros

  • FABJDALC
    

Publications Referenced
SC18761700    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R310 PSY UQ95682

       UP04/12/07 P F412

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 July 2020