A fix is available
APAR status
Closed as program error.
Error description
HPIC terminates ABEND S0C4 ( ABEND0C4 ) if the first Secondary Index and the same data set of shared secondary index are specified as INPUT data set.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS High Performance Image * * Copy for z/OS Version 3 Release 1 * * (FMID=H1J0310). * **************************************************************** * PROBLEM DESCRIPTION: This APAR fixes following problems of * * IMS High Performance Image Copy for * * z/OS Version 3 Release 1: * * 1. When the more than one data set * * within a Shared Secondary Index * * as input data set of AIC or ACIC, * * FABJMAIN terminates with ABEND * * S0C4 ( ABEND0C4 ). * * 2. When the IC function gets OPEN * * fail for input DB or output IC, * * HPIC calls HDPC HASH termination * * and HPPC module terminates with * * ABEND S0C4 ( ABEND0C4 ). * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR provides following fixes for IMS High Performance Image Copy for z/OS Version 3 Release 1: 1. When DBDs within a shared secondary index is specified as input DB for parallel process of IC, HPIC terminates with ABEND S0C4 ( ABENDS0C4 ). The cause of abend is handling shared VSAM data sets between more than one subtasks. 2. When HPIC IC function fails to open input DB or IC data set, HPIC calles HDPC hash termination call and fails ABEND S0C4 ( ABENDS0C4 ). HPIC should bypass HPPC call if the input or output data set is open fail. Because any IC process or HASH is not processed in this situation.
Problem conclusion
FABJDMPN has been modified to specified share the subpool 0 for sharing VSAM data set between HPIC subtasks. FASBJDMP7, FABJDMP8, and FABJDMP9 have been reassembled. FABJDPSN has been modified not to CALL hppc termination call when the HPIC IC process is not done for the DBDS. FASBJDPS7, FABJDPS8, and FABJDPS9 have been reassembled. ***************************************** *** ATTENTION ATTENTION ATTENTION *** ***************************************** When you run IC process for shared secondary index data set, we recommend to use VIC=Y or HDPC=O for other than first DBD within a shared secondary index. IC data set for first DBD of shared secondary index can be used for the recovery, but others are not used for recovery. If the VIC=Y or HPPC=O for the secondary index, the IC data set is not created but the data can be evaluated by HPPC Hash Check.
Temporary fix
Comments
APAR Information
APAR number
PQ88834
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2004-05-13
Closed date
2004-06-10
Last modified date
2004-08-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ89442
Modules/Macros
FABJDMPN FABJDMP7 FABJDMP8 FABJDMP9 FABJDPSN FABJDPS7 FABJDPS8 FABJDPS9
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R310 PSY UQ89442
UP04/06/11 P F406
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.