A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C4-04 at offset X'24EA' in FABJDPS8. The error occurs when HPIC tries to close the image copy data set, that is allocated in multi volumes, because the HPIC uses JFCBEXAD as an address of the extended JFCB. When the JFCB is taken above the 16 MB line, SVA is set to JFCBEXAD.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy * * for z/OS version 3 users (FMID=H1J0310) * **************************************************************** * PROBLEM DESCRIPTION: This APAR fixes following problems: * * - HPIC IC/CRC function fails with ABEND * * S0C4 ( ABEND0C4 ), if the image copy * * data set is multi volumes. * * - HPIC RCV function fails with RC=16 or * * ABEND S0C4 ( ABEND0C4 ), if the * * recovered DB is multi volume OSAM * * and the database records are stored * * into a part of the volumes. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HPIC has following two troubles: - HPIC IC/CRC function fails with ABEND S0C4 ( ABEND0C4 ), if the input image copy data set is multi volumes. - HPIC RCV function fails with RC=16 or ABEND S0C4 ( ABEND0C4 ), if the recovered DB is multi volume OSAM and the database records are stored into a part of the volumes. Because HPIC uses JFCBEXAD as an address of extended JFCB when the JFCB is taken above 16 MB line. In this case HPIC should use SVA as token for getting JFCBEXAD and get correct extended JFCB area.
Problem conclusion
The modules FABJCRC1 FABJDOPN FABJFIG1 FABJXLIM have been modified to use SVA as extend JFCB TOKEN for getting JFCBEXAD. IMS Image Copy Extensions for z/OS Version 2 Release 1 User's Guide (Document Number: SC18-7617-00) should be changed as follows: ============================================================== Appendix A. Return Codes, Abend Codes, and Messages MSG FABJ0178E, FABJ0179E added. | FABJ0178E mac-name ERROR item=item-name RC=nnnnnnnn REASON= | nnnnnnnn | | Explanation: mac-name macro for getting item-name item is | failed. | System Action: FABJMAIN stops processing with a return code | of 16. | Programmer Response: Contact to IBM. | FABJ0179E EXTENT LIMIT CHECK PROCESS FAIL RC=nnnnnnnn | | Explanation: Incorrect DD name is passed to EXTENT limit check | process. | System Action: FABJMAIN stops processing with a return code | of 16. | Programmer Response: Check and correct the DD name of | recovered DB. Rerun the job.
Temporary fix
Comments
APAR Information
APAR number
PQ87876
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2004-04-22
Closed date
2004-04-26
Last modified date
2004-08-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ87757
Modules/Macros
FABJCRC1 FABJDOPN FABJFIG1 FABJXLIM FABUFIG1
SC18761700 |
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R310 PSY UQ87757
UP04/04/27 P F404
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: