A fix is available
APAR status
-
Closed as program error.
Error description
-
HP Load issuesU3737 amd msgHPSR3737E indicating that record size is an ODD length. SHISAM supports ODD record lengths but HISAM does not.
Local fix
Problem summary
-
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance * * Load for OS/390 Release 1 (FMID=H1IM110). * **************************************************************** * PROBLEM DESCRIPTION: HP Load terminates with ABEND U3737 * * (ABENDU3737) MSGHPSR3737E because * * record size of SHISAM is an odd length. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HP Load checks a odd length record for SHISAM DB and terminates with ABEND U3737 (ABENDU3737) and MSGHPSR3737E. But the odd length of SHISAM record is allowed by IMS.
Problem conclusion
-
HP Load utility has been modified as follows: - HPSRPDBD has been modified not to check a odd length record for SHISAM database.
Temporary fix
Comments
APAR Information
-
APAR number
PQ79792
-
Reported component name
IMS HIGH PERF L
-
Reported component ID
5655E0700
-
Reported release
110
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2003-10-17
-
Closed date
2003-10-30
-
Last modified date
2003-11-02
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UQ81668
Modules/Macros
-
HPSRPDBD HPSRPDB6 HPSRPDB7 HPSRPDB8
Fix information
-
Fixed component name
IMS HIGH PERF L
-
Fixed component ID
5655E0700
Applicable component levels
-
R110 PSY UQ81668
UP03/10/31 P F310
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS HP Load"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]
Document Information
Modified date:
03 April 2021