IBM Support

PQ74117: IQCFCKPT OUTPUT SHOWS INVALID YEAR 003 INSTEAD OF 2003 FOR CHECKPOINT RECORD

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IQCFCKPT output chkpt record has incorrect year displayed.
    The output may show as follows:
    CHKPT    D=2003.115,T=19:22:52.441502,Z=+09:00              SIMP
    CHKPT    D= 003.115,T=19:00:00.075348,Z=+09:00              RSRT
    where one or more lines has '003' instead of '2003 specified for
    the year.
    This in turn could cause the following IQCSELCT job to end with
    an RC=08 (checkpoint not found).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users, that are using QCF IQCFCKPT program   *
    *                 to find checkpoints on archived              *
    *                 log data sets.                               *
    *                 In some cases the output is incorrect-       *
    *                 invalid year (lost 2 of year 2003)           *
    *                 The output for IQCFCKPT is as follows.       *
    *                 CHKPT    D=2003.115,T=19:22:52.441502,Z=+09: *
    *                 CHKPT    D= 003.115,T=19:00:00.075348,Z=+09: *
    *                                                              *
    *                 CHKPT    D= 003.115,T=19:26:31.206562,Z=+09: *
    *                 CHKPT    D= 003.115,T=19:34:59.409196,Z=+09: *
    *                 As a result, following IQCSELECT job failed  *
    *                 with cc=8.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: In some cases IMS puts a mask x'80' in  *
    *                      the first byte of year (in log records  *
    *                      x'4200'). IQCFCKPT unpacks the year-    *
    *                      x'A003115F' is converted to             *
    *                      .003.115. The first byte of year is     *
    *                      not correct.                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Because of mask X'80' in the first byte of timestamp in log
    records x'4200', the converted date/time information for the
    checkpoint is not correct.
    

Problem conclusion

  • IQCFCKPT has been changed to reset the mask in the first byte
    of timestamp information for log records X'4200'
    and to create a valid year in date / time information for the
    checkpoins.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ74117

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2003-05-13

  • Closed date

    2003-05-16

  • Last modified date

    2003-06-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ76959

Modules/Macros

  •    IQCFCKPT
    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R120 PSY UQ76959

       UP03/05/19 P F305

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"120"}]

Document Information

Modified date:
14 December 2020