IBM Support

PQ73756: WHEN INSERT RECEIVES AIB STATUS 0900, THE JOB ENDS WITH CC=00 AND THE AIB STATUS GOES UNDETECTED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When IQCINSRT receives AIB RETURN 0900 REASON 0000 TPCBSTAT
    A3: the status code goes undetected and the job ends with rc=00.
    It is suggested that a warning message (rc=04) is issued when
    a non-zero return code from IMS is returned to QCF.
    Keywords: zero cc=00 rc cc
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users, running batch jobs to select      *
    *                 and insert messages on the queue.            *
    *                 -When INSERT receives AIB RETCODE =0900,     *
    *                 the step ends with CC=0                      *
    *                 and the AIB retcode goes undetected.         *
    *                 -Detailed SELECT report is not printed       *
    *                 in some cases - only statistics are          *
    *                 printed.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: It is normal for some messages not      *
    *                      to be inserted on the queue for         *
    *                      reasons like not defined destinations   *
    *                      and etc. IMS returns retcode=x'00F0'    *
    *                      and the reason code for rejecting the   *
    *                      message.                                *
    *                      It is NOT normal to receive retcode     *
    *                      different from x'00F0' back from IMS.   *
    *                      The step's return code RC=00 lets       *
    *                      this situation go undetected.           *
    *                      In some cases the detailed SELECT repor *
    *                      (report by destinations) is not printed *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    -IQCINSRT step ends with RC=04 if IMS return code is different
    from x'00f0'.
    -IQCSELCT detailed report is printed for all destination types.
    

Problem conclusion

  • Programs are changed:
    -IQCSELECT step ends with RC=04 in all cases IMS return code is
    not X'00f0'
    -IQCSELCT prints all reports for all destination selected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ73756

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2003-05-01

  • Closed date

    2003-05-28

  • Last modified date

    2003-06-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ77264

Modules/Macros

  • IQCILEVS IQCINSDC IQCINSRT IQCINS51 IQCINS61
    IQCSEL61
    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R120 PSY UQ77264

       UP03/05/29 P F305

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"120","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"120","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
05 June 2003