IBM Support

PQ72378: ENHANCE IMS HIGH PERFORMANCE SYSGEN TO AUTOMATICALLY COMPRESS TARGET MODBLKS/MATRIX LIBRARIES IF AN SD37 OR SE37 OCCURS.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • =========================
    PROBLEM SYMPTOMS:
    =========================
    ENHANCE IMS HIGH PERFORMANCE SYSGEN TO
    AUTOMATICALLY COMPRESS TARGET MODBLKS/
    MATRIX LIBRARIES IF AN ABENDD37 OR
    ABENDE37 OCCURS.
    ENHANCE IMS HIGH PERFORMANCE SYSGEN TO ALLOW GDG
    DSNAMES TO BE SPECIFIED IN SYSGEN INPUT DSN=
    PARAMETERS.
    =========================
    USERS AFFECTED:
    =========================
    IMS HIGH PERFORMANCE SYSGEN TOOLS USERS.
    =========================
    RECOMMENDATION:
    =========================
    EITHER COMPRESS THE AFFECTED LIBRARY
    MANUALLY WITH IEBCOPY (DISP=SHR IN
    IEBCOPY JCL) OR INSTALL THIS
    MAINTENANCE.
    =========================
    PROBLEM RESOLUTION:
    =========================
    ADD ENHANCEMENTS TO PERFORM COMPRESS
    ON TARGET LIBRARY.
    =========================
    JCLIN CHANGES:
    =========================
    CHANGE LMOD IOHFGEN FROM
    INCLUDE AIOHMOD1(IOHFGEN)
    ENTRY IOHFGEN
    NAME IOHFGEN(R)
    TO
    INCLUDE AIOHMOD1(IOHFGEN)
    SETCODE AC(1)
    ENTRY IOHFGEN
    NAME IOHFGEN(R)
    =========================
    DOCUMENTATION UPDATES:
    =========================
    MANUAL UPDATES:
    ===============
    PAGE 9 - FAST SYSGEN DATA SET PLACEMENT AND AUTHORIZATION
    ADD AFTER FIRST PARAGRAPH.
    FOR BATCH USE OF THE FAST SYSGEN UTILITY, THE SIOHLOAD
    DATA SET MUST BE APF AUTHORIZED FOR AUTOMATIC COMPRESSION
    OF OUTPUT LIBRARIES TO TAKE PLACE AFTER A D37 OR E37 ABEND.
    UPDATED MESSAGE:
    ================
    IOH246E ABEND SAAA RCRR DDNAME DDDDDDDD
    EXPLANATION: AN ABEND WAS INTERCEPTED DURING AN I/O OPERATION
    FOR THE INDICATED DDNAME.
    MODULE: IOHLMOD
    SYSTEM ACTION: THE FAST SYSGEN PROCESS UNLESS THE ABEND CODE
    IS D37 OR E37.  FOR D37 OR E37 ABENDS, IF THE TASK IS APF
    AUTHORIZED, THE OUTPUT LIBRARY IS COMPRESSED AND THE SYSGEN
    OUTPUT PROCESSING IS RETRIED.
    USER RESPONSE: REVIEW THE JES LOG OF THE FAILING JOB FOR OTHER
    MESSAGES RELATED TO THE INDICATED DDNAME.
    NEW MESSAGES:
    =============
    IOH247E TASK NOT APF AUTHORIZED - UNABLE TO CORRECT SPACE ABEND
    EXPLANATION: A D37 OR E37 ABEND OCCURRED WHILE WRITING TO AN
    OUTPUT LIBRARY.  AUTOMATIC OUTPUT LIBRARY COMPRESSION DETERMINED
    THAT THE JOB STEP WAS NOT AUTHORIZED, SO COMPRESSION WAS NOT
    ATTEMPTED.
    MODULE: IOHLMOD
    SYSTEM ACTION: THE JOB STEP ABENDS.
    USER RESPONSE: ENSURE THAT EVERY STEPLIB AND JOBLIB DATASET IS
    APF AUTHORIZED TO ENABLE AUTOMATIC COMPRESSION, OR RUN A BATCH
    COMPRESS JOB FOR THE LIBRARY THAT EXPERIENCED THE X37 ABEND.
    IOH248E SPACE ABEND RECURRED AFTER OUTPUT LIBRARY WAS COMPRESSED
    EXPLANATION: A D37 OR E37 ABEND OCCURRED WHILE WRITING TO AN
    OUTPUT LIBRARY.  THE LIBRARY WAS COMPRESSED, BUT THE X37 ABEND
    REOCCURRED.
    MODULE: IOHLMOD
    SYSTEM ACTION: THE JOB STEP ABENDS.
    USER RESPONSE: ENLARGE THE LIBRARY THAT EXPERIENCED THE ABEND.
    IOH249E COMPRESS FAILED - LINK TO IEBCOPY ABENDED SXXX
    EXPLANATION: A D37 OR E37 ABEND OCCURRED WHILE WRITING TO AN
    OUTPUT LIBRARY.  AN AUTOMATIC COMPRESS WAS ATTEMPTED, BUT THE
    LINK MACRO EXPERIENCED THE ABEND NOTED IN THE MESSAGE.
    MODULE: IOHLMOD
    SYSTEM ACTION: THE JOB STEP ABENDS.
    USER RESPONSE: CONTACT THE SUPPORT CENTER FOR ASSISTANCE.
    =========================
    MODULES/MACROS:
    =========================
    MODULES:
    IOHDCB
    IOHFGEN (ONLY THE JCLIN CHANGE)
    IOHLMOD
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS HIGH PERFORMANCE SYSGEN TOOLS USERS.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Enhance IMS High Performance Sysgen to  *
    *                      automactically compress target modblks/ *
    *                      matrix libraries if an ABENDD37 or      *
    *                      ABENDE37 occurs.                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Enhance IMS High Performance Sysgen to automatically compress
    target modblks/matrix libraries if an ABENDD37 or ABENDE37
    occurs.
    Enhance IMS High Performance Sysgen to allow GDG DSNAMES to be
    specified in sysgen input DSN= parameters.
    

Problem conclusion

  • Add enhancements to perform compress on target library and
    allow GDG dsnames. There are also documentation changes.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ72378

  • Reported component name

    IMS HP SYSGEN T

  • Reported component ID

    5655F4300

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2003-03-24

  • Closed date

    2003-04-08

  • Last modified date

    2003-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ75806

Modules/Macros

  • H24Q110J IOHDCB   IOHLMOD  IOHPARM
    

Publications Referenced
SC27117001    

Fix information

  • Fixed component name

    IMS HP SYSGEN T

  • Fixed component ID

    5655F4300

Applicable component levels

  • R110 PSY UQ75806

       UP03/04/10 P F304

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89J","label":"IMS HP System Generation Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]

Document Information

Modified date:
22 October 2020