A fix is available
APAR status
Closed as program error.
Error description
The image copy datasets are now always allocated DISP=NEW, so that only the first IC executes. All subsequent jobs fail JCL error because the IC data set already exist.
Local fix
None None
Problem summary
**************************************************************** * USERS AFFECTED: ALL CONTROL SUITE R220 USERS * **************************************************************** * PROBLEM DESCRIPTION: WHEN USING NON-GDG IC BACKUP FILES ON * * DASD DEVICES, THE DISPOSITION KEYWORD * * ON THE OUTPUT DD STATEMENT IS ALWAYS * * DISP=(,CATLG). CUSTOMER * * WOULD LIKE TO BE ABLE TO REUSE THE * * DASD FILES ONCE THEY ARE CREATED THE * * FIRST TIME BY HAVING THE PRODUCT DETECT * * THEM DURING SUBSEQUENT JOBSTREAM JCL * * CREATION AND SET THE DISPOSITION KEY- * * WORD TO DISP=OLD. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** CONTROL SUITE WAS NOT BUILDING DISP=OLD FOR REUSEABLE NON-GDG IMAGE COPY DATASETS.
Problem conclusion
CORRECTIONS IN JCL SKELETONS WERE MADE TO ALLOW DISP=OLD FOR IMAGE COPY NON-GDG NON-$TIME DATA SETS. THE FOLLOWING ITEMS ARE ALSO ADDRESSED IN THIS APAR. 1.)COMBINATIONS OF "$TIME" OR "NN.$TIME" FOR DASD OR TAPE DATA SET LOW LEVEL QUALIFIERS WERE ENABLED. 2.)ADDED ERROR MESSAGE FOR ISPF PANEL IDLSOPT1 TO MAKE UNLOAD DATA SET LOW LEVEL QUALIFIERS MUTUALLY EXCLUSIVE. 3.)HELP PANEL UPDATES FOR ISPF PANEL, "IDLSOPT3". 4.)MISSING DEQUEUE CORRECTED IN COLLECT FUNCTION WHEN USER EXITS COLLECTION PROCESSING. THE FOLLOWING TEXT UPDATES WILL BE MADE TO THE MANUAL. On page 21 in figure 11 the DASD and TAPE LOQUAL data entry variables have been replaced with single data entry variable identified as "IC Low Level Qual". On page 22 the descriptions for "IC Low Level Qual (DASD)" and "(TAPE)" have been amended to refer to a single reference. variables have been replaced with single data entry variable identified as "IC Low Level Qual".
Temporary fix
Comments
APAR Information
APAR number
PQ70881
Reported component name
IMS DB CNTL SUI
Reported component ID
5655F7600
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2003-02-11
Closed date
2003-03-06
Last modified date
2003-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ74785
Modules/Macros
IDLC0001 IDLGNJCC IDLGNJCX IDLH1670 IDLH1672 IDLH1678 IDLICD IDLICD2 IDLICEDD IDLIRE03 IDLIRE04 IDLIRE05 IDLPCJCE IDLRCDS1 IDLSDSS0 IDLSMAIN IDLSOPT1 IDLSOPT3
SC27118105 |
Fix information
Fixed component name
IMS DB CNTL SUI
Fixed component ID
5655F7600
Applicable component levels
R220 PSY UQ74785