A fix is available
APAR status
Closed as program error.
Error description
After error message "IQC3063E TimeStamp:invalid symbol in T=..parameter" is issued, the job ends with rc=00. An RC=08 (RC08) should be returned. Additional Problems fixed: 1) IQCSELCT RC=08 may occur if job region size is too small (an increase in region size should alleviate this condition). The problem is that when the cc08 is issued, there is no WTO message or QCFPRINT data to help determine this failure. This APAR will add a change to return some sort of error message indicating the small region size. 2) IQCSELCT may get an RC08 if the LOGOUT data set is defined with a smaller LRECL and BLKSIZE then the input messages LRECL and BLKSIZE (correcting this condition will fix the problem). The problem is that when the cc08 is issued, there is no WTO message or QCFPRINT data to help determine this failure. This APAR will add a change to return some sort of error message indicating this condition.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of QCF, using IQCSELCT program for * * functions REPROCESS, RECOVER, RECOVERAB, * * RECOVERDM. Better diagnostic for input * * control cards errors is included, new * * error message is issued if not enough * * storage for initialization, error message * * is printed if LOGOUT and SCRAPSEL data sets * * do not have correct LRECL size. * **************************************************************** * PROBLEM DESCRIPTION: - After message"IQC3063E * * TimeStamp:invalid symbol in T=.. * * parameter" QCF continues with selecting * * messages, should end with return code * * = 08. * * - If there is not enough region for * * the initialization, step ends with * * return code = 08 and no error message. * * - If LRECL for LOGOUT or SCRAPSEL data * * sets is smaller than LRECL of LOGIN * * data set +320 - step ends with return * * code = 08 and no error message. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** Programs are changed to: - stop proccessing messages if there is some error in the input control cards. - issue message IQC3114E if there is not enough storage for initialization. - issue messages IQC3045E and IQC3048E if LRECL for LOGOUT or SCRAPSEL is smaller than input record + 320 bytes for QCF prefix.
Problem conclusion
Programs are changed to fix the errors.
Temporary fix
Comments
APAR Information
APAR number
PQ70352
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2003-01-28
Closed date
2003-02-10
Last modified date
2003-03-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ74035
Modules/Macros
IQCSELCT IQCSEL61 IQCSMSG0
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R120 PSY UQ74035
UP03/02/12 P F302
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"120","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"120","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: