APAR status
Closed as new function.
Error description
We will be providing additional IVP support by including a BATCH jobstream which will create a IMS Full Function database via DFSDDLT0. We will then build a dictionary from it and create a compression routine with which to compress it with and then uncompress it and compare the resulting database against a copy of the original created database before compression was done.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL USERS OF IMS HARDWARE DATA COMPRESSION * * EXTENDED FOR Z/OS, VERSION 2 RELEASE 2 * **************************************************************** * PROBLEM DESCRIPTION: USER REQUEST FOR ADDITIONAL IVP SUPPORT * * THROUGH A JCL BATCH JOBSTREAM PROCESS * * WHICH WILL CONSTRUCT AN IMS FULL * * FUNCTION DATABASE, BUILD A HSDCE * * DICTIONARY FROM IT AND CREATE A * * COMPRESSION ROUTINE FOR IT AND RELOAD * * AND UNLOAD THE IMS FF DATABASE WITH THE * * COMPRESSION ROUTINE IN ORDER TO * * VALIDATE THE INSTALLATION OF THE HSDCE * * PRODUCT. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** CONSTRUCT A BATCH IVP JOBSTREAM TO VALIDATE INSTALLATION OF THE IMS HARDWARE DATA COMPRESSION EXTENDED FOR Z/OS PRODUCT. THIS BATCH IVP WILL CREATE A FULL FUNCTION DATABASE, UNLOAD IT, CREATE AND BUILD A CUSTOMIZED COMPRESSION DICTIONARY, AND BUILD A COMPRESSION ROUTINE WITH IT, RELOAD THE DATABASE USING THE COMPRESSION ROUTINE, UNLOAD THE COMPRESSED DATABASE TO REXPAND IT AND COMPARE IT TO THE ORIGINAL FULL FUNCTION DATABASE CREATED AT THE BEGINNING OF THE IVP JOBSTREAM PROCESS.
Problem conclusion
Temporary fix
Comments
=============================================================== ADD THE FOLLOWING UPDATE TO THE USER'S GUIDE, SC27-1005-02, FOR VERSION 2 RELEASE 2 AT THE BOTTOM OF PAGE 16, FOR SECTION TITLE VERIFYING INSTALLATION (IVP). BATCH JOBSTREAM INSTALLATION VERIFICATION PROCEDURE (IVP). ---------------------------------------------------------- THE IMS HARDWARE DATA COMPRESSION EXTENDED PRODUCT REQUIRES A COHESIVE, OPERATIONAL IMS SYSTEM TO BE FULLY FUNCTIONAL. IF SUCH A SYSTEM IS NOT AVAILABLE TO THE PRODUCT INSTALLER AND INITIAL TESTER, THE IBM-SUPPLIED BATCH IVP JOB CAN BE RUN TO CREATE AN IMS FULL FUNCTION DATABASE WITH WHICH TO CREATE A DICTIONARY AND COMPRESSION ROUTINE TO VALIDATE THE PRODUCT INSTALLATION. THE BATCH IVP JOBSTREAM, HCOIVPBA, CAN BE FOUND IN THE SMP/E SHCOSLIB DATA SET. INSTRUCTIONS FOR CUSTOMIZING THIS JOBSTREAM TO THE STANDARDS OF YOUR FACILITY ARE INCLUDED IN COMMENTS AT THE BEGINNING OF THE JOBSTREAM. THE FULL FUNCTION DATABASE, IT'S DBD, AND OUTPUT DATASETS FROM THE VARIOUS UNLOAD STEPS (STEP15 AND STEP17) CAN ALSO BE USED WITH THE ISPF DIALOG FOR FURTHER PRODUCT FAMILIARITY. ===============================================================
APAR Information
APAR number
PQ65698
Reported component name
IMS HDCE
Reported component ID
5655E0200
Reported release
220
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2002-08-28
Closed date
2002-09-27
Last modified date
2002-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ70290
Modules/Macros
HCOIVPBA
SC27100502 |
Fix information
Fixed component name
IMS HDCE
Fixed component ID
5655E0200
Applicable component levels
R220 PSY UQ70290
UP02/10/02 P F210