IBM Support

PM99279: KO2O1348E NEAR-TERM HISTORY DATA COLLECTOR - READA/READS FAILED REASON CODE 00E60824 (CHECKRET)

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • KO2O1348E NEAR-TERM HISTORY DATA COLLECTOR - READA/READS FAILED.
    REASON CODE 00E60824 (CHECKRET).
    .
    Near-Term History (NTH) fails to start due to error message seen
    in OMPE Server STC joblog:  KO2O1348E NEAR-TERM HISTORY DATA
    COLLECTOR - READA/READS FAILED. REASON CODE 00E60824 (CHECKRET).
    .
    This error was caused by the RKD2PAR(COPTssid) member specifying
    the parm ACCTG() which was generated by PARMGEN when customer
    does not choose to turn on accounting traces.
    

Local fix

  • Specify ACCTG(1) in RKD2PAR(COPTssid) member and recycle OMPE
    Server STC.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - NTH - Near Term History                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: MESSAGE KO2O1348E IS ISSUED WHEN        *
    *                      COLLECTING STATISTIC DATA ONLY.         *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    MESSAGE KO2O1348E IS ISSUED WHEN COLLECTING STATISTIC DATA
    ONLY. THE COLLECTOR IS ATTEMPTING TO COLLECT DATA FROM AN
    INVALID OPX BUFFER.
    
    PROBLEM CONCLUSION:
    ADD CODE TO SKIP THE OPX DATA COLLECTION.
    
    KEYWORDS:
    KO201348E STATISTICS ACCTG()
    

Problem conclusion

  • PROBLEM CONCLUSION:
    ADD CODE TO SKIP THE OPX DATA COLLECTION.
    
    KEYWORDS:
    KO201348E STATISTICS ACCTG()
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM99279

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-10-16

  • Closed date

    2013-12-19

  • Last modified date

    2014-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI13698 UI13699

Modules/Macros

  •    KO2ICOLA KO2ICOLK KO2ICOLS KO2ICOL2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UI13698

       UP13/12/20 P F312

  • R520 PSY UI13699

       UP13/12/20 P F312

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1"}]

Document Information

Modified date: