A fix is available
APAR status
Closed as program error.
Error description
KO2O1348E NEAR-TERM HISTORY DATA COLLECTOR - READA/READS FAILED. REASON CODE 00E60824 (CHECKRET). . Near-Term History (NTH) fails to start due to error message seen in OMPE Server STC joblog: KO2O1348E NEAR-TERM HISTORY DATA COLLECTOR - READA/READS FAILED. REASON CODE 00E60824 (CHECKRET). . This error was caused by the RKD2PAR(COPTssid) member specifying the parm ACCTG() which was generated by PARMGEN when customer does not choose to turn on accounting traces.
Local fix
Specify ACCTG(1) in RKD2PAR(COPTssid) member and recycle OMPE Server STC.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - NTH - Near Term History * **************************************************************** * PROBLEM DESCRIPTION: MESSAGE KO2O1348E IS ISSUED WHEN * * COLLECTING STATISTIC DATA ONLY. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: MESSAGE KO2O1348E IS ISSUED WHEN COLLECTING STATISTIC DATA ONLY. THE COLLECTOR IS ATTEMPTING TO COLLECT DATA FROM AN INVALID OPX BUFFER. PROBLEM CONCLUSION: ADD CODE TO SKIP THE OPX DATA COLLECTION. KEYWORDS: KO201348E STATISTICS ACCTG()
Problem conclusion
PROBLEM CONCLUSION: ADD CODE TO SKIP THE OPX DATA COLLECTION. KEYWORDS: KO201348E STATISTICS ACCTG()
Temporary fix
Comments
APAR Information
APAR number
PM99279
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
511
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-10-16
Closed date
2013-12-19
Last modified date
2014-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI13698 UI13699
Modules/Macros
KO2ICOLA KO2ICOLK KO2ICOLS KO2ICOL2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1"}]
Document Information
Modified date:
31 March 2021