Problem Description: DWA Interop crashes, when you click on 'Associated Requirements' links for a RCR from Rational Change Steps to Reproduce: - Install DOORS Server 9.5.1 and DWA 9.5.1 on Solaris 10 machine - Create a module and configure it for Change Management - In Rational Change create the RCR, assign it your self and change the status to rcr_Assigned state - In DOORS when you open the module it will ask you to select the Default RCR, select the one you just created - Now make some changes to DOORS object text and save the module - In Change, go to the RCR, click on the module link under 'Associated Requirements', you will see a DWA log in screen popping up , but nothing happens after you put in the credentials - In the Solaris box you will see that the Interop has crashed. Workaround: Use either Linux or Windows Server for DWA.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Only Solaris environment is affected. * **************************************************************** * PROBLEM DESCRIPTION: * * DWA Interop crashes, when you click on "Associated * * Requirements" links for a RCR from Rational Change * **************************************************************** * RECOMMENDATION: * **************************************************************** std::deque front insertion operation was not properly working with Solaris 10. Known issue with it.
Problem conclusion
Changed the algorithm, not to use front insertion and work out the business logic.
Temporary fix
Comments
APAR Information
APAR number
PM96375
Reported component name
TLOGIC DOORS WE
Reported component ID
5724V97WA
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-09-04
Closed date
2014-06-07
Last modified date
2014-06-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS WE
Fixed component ID
5724V97WA
Applicable component levels
R960 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQBZ","label":"Rational DOORS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.5","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
02 November 2021