A fix is available
APAR status
Closed as program error.
Error description
When IP address of LPAR is changed then Activity Browser loses all CQM Subsystems from that LPAR.
Local fix
1. Stop the CAE Server 2. Remove the following folders: a. knowledge\domains\Query+Monitor b. bbdb 3. Restart the CAE Server
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Query Monitor. * **************************************************************** * PROBLEM DESCRIPTION: When IP address of LPAR is changed * * then Activity Browser loses * * all CQM Subsystems from that LPAR. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PM96161
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-08-30
Closed date
2013-10-24
Last modified date
2013-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI11660
Modules/Macros
CQMBLOB CQMCAEPT CQMJAR
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R310 PSY UI11660
UP13/11/06 P F311
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020