IBM Support

PM95565: QUERY MONITOR STOPS MONITORING WHILE GUARDIUM STAP IS ACTIVE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In some environments, Query Monitor stops collecting when
    Guardium STAP is active.
    

Local fix

  • The workaround will be to cycle the Guardiam S-TAP before CQM is
    started. With QM stopped:
    1) Stop STAP
    2) Wait for the message:
    ADHQ5011I MONITORING AGENT DEINSTALLATION COMPLETE FOR SUBSYSTEM
    nnnn
    3) START the STAP
    4) START The CQM
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: In some environments, Query Monitor     *
    *                      stops collecting when Guardium STAP     *
    *                      is active.                              *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM95565

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-08-21

  • Closed date

    2013-10-28

  • Last modified date

    2013-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • CQMISMAX
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R310 PSY UI11787

       UP13/11/08 P F311

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.