A fix is available
APAR status
Closed as program error.
Error description
If ISPF is used to generate Image Copy JCL the following error messages are received: . IEC130I SYSPRINT DD STATEMENT MISSING +DFS301A UNABLE TO OPEN DDNAME SYSPRINT . Generated JCL: . 2 //IDC EXEC PGM=IDCAMS, // COND=(4,LE),DYNAMNBR=999 3 //SYSPRINT DD SYSOUT=* 4 //SYSIN DD * //*======================================================= //* //* IMAGE COPY //* //*======================================================= 5 //IMC EXEC PGM=DFSUDMP0,PARM='DBRC=Y', // COND=(4,LE), // REGION=60M 6 //STEPLIB DD DISP=SHR,DSN=IMS.IMSA.SDFSRESL 7 //SMPINVA DD DISP=SHR, // DSN=DNET089.SMPINVP1.A00001 8 //IMC11 DD DISP=(,CATLG,KEEP),UNIT=SYSDA, // SPACE=(CYL,(1,200),RLSE), // DSN=DNET089.SMPINVP1.A00001.IC1 9 //SYSIN DD * . Additionally, if Haldb Toolkit is setup to generate a High Performance Image Copy that JCL is incorrect too, it completely omits STEPLIB DD plus other DD statements.
Local fix
There is a work around using the following procedure: 1. Locate member IHCSIMJC in your SIHCSKEL library. 2. Edit the 2nd ")SEL" statement as follows: From: )SEL &IHCHPIC ^= &Z To: )SEL &IHCHPIC NE &Z
Problem summary
**************************************************************** * USERS AFFECTED: All clients of IMS HALDB Toolkit V3R2. * **************************************************************** * PROBLEM DESCRIPTION: If ISPF user interface is used to * * generate Image Copy JCL, the following * * error messages are received: * * -IEC130I SYSPRINT DD STATEMENT MISSING * * -DFS310A UNABLE TO OPEN DDNAME SYSPRINT * * Additionally, if Haldb Toolkit is * * setup to generate a High Performance * * Image Copy, that JCL is incorrect too. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** IHCSIMJC, the file-tailoring skeleton, generates the Image Copy JCL with IMS standard utility or with High Performance Image Copy utility through the ISPF file-tailoring service. Since IHCSIMJC has the incorrect control statement, 'SEL &IHCHPIC = &Z', the JCL is not generated properly.
Problem conclusion
IHCSIMJC has been changed to generate the Image Copy JCL correctly.
Temporary fix
Comments
APAR Information
APAR number
PM94754
Reported component name
IMS HALDB C&M A
Reported component ID
5655I0100
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-08-08
Closed date
2013-08-14
Last modified date
2014-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK96701
Modules/Macros
IHCSIMJC IHCULEV0
Fix information
Fixed component name
IMS HALDB C&M A
Fixed component ID
5655I0100
Applicable component levels
R320 PSY UK96701
UP13/08/16 P F308
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.