A fix is available
APAR status
Closed as program error.
Error description
ISPF online monitor may show incorrect (i.e. abnormally high) Elapsed Class 1 time values for parallel threads : --------Elapsed Class 1 ... 41484 10:4
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - ISPF Monitoring dialogs * **************************************************************** * PROBLEM DESCRIPTION: ISPF OLM thread summary panel DGOMTPLS * * and thread detail panel DGOMTPSM shows * * high class 1 elapsed time like * * "41484 10:4". * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: ISPF OLM thread summary panel DGOMTPLS and thread detail panel DGOMTPSM shows high class 1 elapsed time like "41484 10:4". PROBLEM CONCLUSION: The calculation of the class 1 elapsed time from IFCID 148 has been changed. The rollup flag qwacparr is used for this calculation and qwacbsc and qwacesc is checked for timestamp format. KEYWORDS: OMPE-OLM THREAD DGOMTPLS DGOMTPSM HIGH-ELAPSED-TIME
Problem conclusion
The calculation of the class 1 elapsed time from IFCID 148 has been changed. The rollup flag qwacparr is used for this calculation and qwacbsc and qwacesc is checked for timestamp format. KEYWORDS: OMPE-OLM THREAD DGOMTPLS DGOMTPSM HIGH-ELAPSED-TIME
Temporary fix
Comments
APAR Information
APAR number
PM94657
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
511
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-08-07
Closed date
2013-11-19
Last modified date
2013-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI12663 UI12664 UI12665
Modules/Macros
DGOMTLST DGOMTPOP
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UI12663
UP13/11/20 P F311
R511 PSY UI12664
UP13/11/20 P F311
R520 PSY UI12665
UP13/11/20 P F311
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 December 2013