APAR status
Closed as program error.
Error description
The business partner has started to test the Cenit BW Connection with TM1 10.1.1.1 aka TM1 10.1 RP1 FP1.????So far, they run into two defects when using a german TM1 10.1.1.1 Architect:??Note that the three items (1.1), (1.2.1) and (1.2.2) all describe different aspects of the same defect.????(1.1)??When they open an existing TI process in a german TI Editor, then go to the third tab "Zuordnen" (= Map), then go to the second tab "Dimensionen" (= Dimension), then try to change the value of the column "Aktion" (= Action), eg they try to change the initial german Action value "Unver?ndert" (= As Is).????=> The shortcut menu offers the english Action values "Create", "Recreate", "Update" and "As Is" instead of the german Action values.????(1.2.1)??Select one of the english Action values "Create", "Recreate", "Update" and "As Is" being offered, eg select the value "Update". Click on the button "Save" in the menu bar of the TI Editor to save the modified TI process.????=> After the Save the selected english Action value "Update" has changed back to the initial german Action value "Unver?ndert" (= As Is).????(1.2.2)??Select one of the english Action values "Create", "Recreate", "Update" and "As Is" being offered, eg select the value "Update". Move from the second tab "Dimensionen" to the next tab, eg move to the third tab "Attribute" (=Attributes). Move from the third tab "Attribute" back to the second tab "Dimensionen". ????=> After moving back to the second tab "Dimensionen" the selected english Action value "Update" has changed back to the initial german Action value "Unver?ndert" (= As Is).????(2)??Change the value of the column "Elementtyp" (= Element Type) from "Numerisch" (=Numerical) to "Text" (= String). Click the button "Save" in the menu bar of the TI Editor to save the modified TI process.????=> After the Save the german value "Text" has changed to "Zeichenfolge".??
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All Users * **************************************************************** * PROBLEM DESCRIPTION: * * See error description. * **************************************************************** * RECOMMENDATION: * * Upgrade to TM1 10.1 RP1 FP2 * ****************************************************************
Problem conclusion
Code Fix
Temporary fix
Comments
APAR Information
APAR number
PM93301
Reported component name
TM1 SERVER
Reported component ID
5724W49SE
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-07-18
Closed date
2013-11-06
Last modified date
2013-11-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TM1 SERVER
Fixed component ID
5724W49SE
Applicable component levels
RA11 PSN
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS9RXT","label":"Cognos TM1"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: