PM92382: WHEN RUNNING A FP SENSOR JOB, DYNAMIC ALLOCATION FAILED FOR HFPSXXXX DDS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When running a FP sensor job, dynamic allocation failed for
    HFPSxxxx DDs with the HFPD3023E message and abended with U3023.
    
    Additional symptom addressed:
    DB Sensor/FPA Analyze abend with B37-04 for HFPIxxxx DDs when
    HFPSxxxx DDs are specified in their JCLs.              ABENDB37
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool,  *
    *                 Fast Path Online Tools and DB Sensor in Fast *
    *                 Path Solution Pack Version 1 Release 2       *
    *                 (FMID: HAHQ120).                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. DB Sensor/FPA Analyze abended with   *
    *                      U3023 against the large DEDB due to     *
    *                      dynamic allocation failure for          *
    *                      HFPSxxxx work data sets.                *
    *                      2. OPC and OER with pointer checking    *
    *                      terminated rc=08 against the large DEDB *
    *                      due to dynamic allocation failure for   *
    *                      DAR13SO work data sets.                 *
    *                      3. DB Sensor/FPA Analyze abended with   *
    *                      B37-04 for HFPIxxxx DDs when HFPSxxxx   *
    *                      DDs were specified in a JCL.            *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    1. When both the maximum and minimum length of the segments were
    small and the DEDB area was big, DB Sensor and FPA Analyze
    calculated the primary quantity for HFPSxxxx work data sets and
    determined 3.8G. When they tried to allocate work data sets
    dynamically, the request failed.
    2. When both the maximum and minimum length of the segments were
    small and the DEDB area was big, OPC and OER with pointer
    checking calculated the primary quantity for DAR13SO work data
    set and determined 3.8G. When they tried to allocate work data
    sets dynamically, the request failed.
    3. DB Sensor/FPA Analyze determined HFPIxxxx DDs space
    attribute on basis of HFPSxxxx DDs. When HFPSxxxx DDs were
    specified on the JCL, the model value was not calculated.
    Therefore HFPIxxxx DDs were allocated with small size
    dynamically and abended with B37.
    

Problem conclusion

  • 1. DB Sensor and FPA Analyze are modified to adjust the primary
    and secondary quantities when the calculated primary quantity
    is greater than 1G.
    2. OPC and OER with pointer checking are modified to adjust the
    primary and secondary quantities when the calculated primary
    quantity is greater than 1G.
    3. HFPIxxxx DDs space attribute is determined not to depend on
    the HFPSxxxx DDs.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM92382

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-07-04

  • Closed date

    2013-08-15

  • Last modified date

    2013-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK96746

Modules/Macros

  • FPXATDC0 HFPA1IN0 HFPDYBL0 HFPQA1I0
    

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R120 PSY UK96746

       UP13/08/17 P F308

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]

Document Information

Modified date:
14 December 2020