IBM Support

PM88212: MULTIPLE STARTS OF PESERVER TERMINATES STC ADDRESS SPACE RESULTSIN KO2Z999E U2008 KO2Z091E AND MULTIPLE 0C4 ABENDS IN KO2OCNTB

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In v511 issuing multiple starts of the PESERVER results in:
    .
    KO2Z999E  OMP5 V511 Service error SSM=OMPETOP /OMPETOP
                                                     ABEND=U2008 RSN
    KO2Z091E  OMP5 V511 Collector address space terminating due to
                                                            PESERVER
    IEA995I SYMPTOM DUMP OUTPUT
    SYSTEM COMPLETION CODE=A03
    .
    PSW AT TIME OF ERROR  070C2000   845A3768  ILC 2  INTC 0D
       NO ACTIVE MODULE FOUND
       NAME=UNKNOWN
       DATA AT PSW  045A3762 - 58108010  0A0D58E0  02FC58D0
       GR 0: 7F4C83A0   1: 80A03000
          2: 00F9E580   3: 7F4C8B98
          4: 00AFF208   5: 7F4C8240
          6: 00AFF208   7: 00AC3650
          8: 045A4950   9: 00AC3650
          A: 00000000   B: 00ABE820
          C: 00AC3650   D: 00AC36BC
          E: 8459BE92   F: 845A36F0
    .
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=14.31.44  SEQ=07011  CPU=0000  ASID=00FC
     PSW AT TIME OF ERROR  070D2000   970A8B4A  ILC 6  I
       ACTIVE LOAD MODULE       ADDRESS=170A1D48 OFFSET=00006E02
       NAME=KO2OCNTB
       DATA AT PSW  170A8B44 - 0000B20A  0000D507  A3EEE
       GR 0: 00000010   1: 00ACACF0
          2: 192B2780   3: 00000000
          4: 00000000   5: 00000000
          6: 00000000   7: 00000000
          8: 00000000   9: 16C81768
          A: 970A8B0A   B: 00000000
          C: 00000000   D: 16C81F70
          E: 0008AF60   F: 00AC18B8
    .
    The above abend0c4 in KO2OCNTB may repeat multiple times.
    .
    

Local fix

  • do not issue starts to the PESERVER
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   OMEGAMON collector                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Multiple starts of PESERVER main        *
    *                      Subtask Causes PE Server to abnormally  *
    *                      Terminate.                              *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    PE Server abnormally terminates when a START PESERVER is
    externally issued while PESERVER is already running.
    
    PROBLEM CONCLUSION:
    Reject externally issued PESERVER START commands.
    

Problem conclusion

  • Reject externally issued PESERVER START commands.
    
    KEYWORDS : U2008 KO2Z091E KO2Z999E S0C4 KO2OCNTB
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM88212

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-05-01

  • Closed date

    2013-06-14

  • Last modified date

    2017-07-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK95114

Modules/Macros

  •    KO2ZCMD
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UK95114

       UP13/06/18 P F306

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
10 July 2017