Error description

  • FPEU0101S  INTERNAL ERROR IN MODULE DGOFEDPM, CODE=5, DIAGNOSTIC
    DATA=QBGLCN B
    
    
    Analysis shows that customer got FPEU0101S messages because
    metadata, describing obsolete QBGLCN field,
    were not properly removed from the OMPE code.
    
    DB2 does not provide QBGLCN field since DB2 V8 and QBGLCN field
    should not exist in the OMPE V510 and V511.
    
    Will make code clean-up.
    

Local fix

  • The workaround will be to edit customer's Exception Threshold
    data set hilev.EXCEPT(P1SD).
    
    That can be done by navigating through the next ISPF panels and
    removing QBGLCN selection:
    
    FPEFMENU     IBM Tivoli OMEGAMON XE for DB2 Performance Expert
    for SAP
    4. Maintain parameter data sets
    
    DGOPMENU                Data Set Maintenance Menu
    1. Maintain exception thresholds
    
    DGOPXDS1          Exception Threshold Category Selection
    Group Buffer Pools Activity per System
    
    DGOPXDS2           Exception Threshold Field Selection
    QBGLCN    Castout engine unavailable     <--Clean-up selection
    mark
    
    Another way to disable QBGLCN exception checking is to edit
    hilrv.EXCEPT(P1SD) directly in the ISPF and set '*' in the first
    column of the row that contains QBGLCN in the column 150 to
    disable QBGLCN exception check.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Batch Reporting                          *
    *                 -   ISPF Monitoring dialogs                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Number of "FPEU0101S INTERNAL ERROR IN  *
    *                      MODULE DGOFEDPM, CODE=5, DIAGNOSTIC     *
    *                      DATA=QBGLCN B" error messages observed  *
    *                      in the PE Batch Report.                 *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    That happened because metadata, describing obsolete DB2 fields
    QBAC(HRF,HWF), QBGL(AD,AZ,CN,RF,SU), QBST(ARF,AWF,HPA,HPL,HRF,
    HWF), were not properly removed from the code.
    
    PROBLEM CONCLUSION:
    Code changed to fix this problem.
    

Problem conclusion

  • Code changed to fix this problem.
    
    KEYWORDS :
    BATCH STATISTICS EXCEPTIONS REPORT FPEU0101S QBGLCN
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM84155

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-03-05

  • Closed date

    2013-05-03

  • Last modified date

    2017-06-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK94040 UK94041 UK94042 UK94043

Modules/Macros

  •    DGOEC000 DGOEINIT DGOELOGW DGOETERM DGOFEBLD
    DGOFEDAT DGOFEETD DGOFFLDS DGOFPETD DGOFPINT DGOFPRPT DGOFPTRM
    DGOMEFTA DGOMEFXL DGOMEGIN DGOMEGTM DGOMEXA0 DGOMEXSS DGOMEXST
    DGOMLAXD DGOMLEXD DGOMSX00 DGOMTX00 DGOVUELD DGOVUINI DGOVUM00
    FPEFNENU FPEFNJPN FPEMEXA0 FPEUFLSP FPEUFLS2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R51J PSY UK94041

       UP13/05/07 P F305

  • R51W PSY UK94043

       UP13/05/07 P F305

  • R510 PSY UK94040

       UP13/05/07 P F305

  • R511 PSY UK94042

       UP13/05/07 P F305

Fix is available