IBM Support

PM76269: PERFORMANCE WAREHOUSE ENTERS LOOP WITH ABENDS S301 AFTER INITIALABEND S202

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Performance Warehouse abends S202 in module FPEZPMS then
    loops with repetitve S301 abends
    
     04.03.40 STC17995  FPEV9999I **** DB2 PM/PE SYMPTOM RECORD ****
     04.03.40 STC17995  FPEV9999I LVLS/OMEGAMON XE PE/PM
     04.03.40 STC17995  FPEV9999I VALU/PCHK
     04.03.40 STC17995  FPEV9999I AB/S/202
     04.03.40 STC17995  FPEV9999I AB/U/000
     04.03.40 STC17995  FPEV9999I RIDS/FPEZPMS#l
     04.03.40 STC17995  FPEV9999I RIDS/
     04.03.40 STC17995  FPEV9999I PTFS/DA  ?
     04.03.40 STC17995  FPEV9999I ADRS/
     04.03.40 STC17995  FPEV9999I PSW /078C2000 814AF356
     04.03.40 STC17995  FPEV9999I REGS 0-1/00000000 00000BD8
     04.03.40 STC17995  FPEV9999I REGS 2-3/80010080 915766AA
     04.03.40 STC17995  FPEV9999I REGS 4-5/00000000 0057666A
     04.03.40 STC17995  FPEV9999I REGS 6-7/1076D4C8 00FC7880
     04.03.40 STC17995  FPEV9999I REGS 8-9/014B0D48 00000000
     04.03.40 STC17995  FPEV9999I REGS A-B/7F44BA18 7FFFBAF8
     04.03.40 STC17995  FPEV9999I REGS C-D/00000BE0 00091330
     04.03.40 STC17995  FPEV9999I REGS E-F/00FF1000 91491098
     04.03.40 STC17995  IEA995I SYMPTOM DUMP OUTPUT  256
        256             SYSTEM COMPLETION CODE=202  REASON
    CODE=00000000
        256              TIME=04.03.40  SEQ=61906  CPU=0081
    ASID=026D
        256              PSW AT TIME OF ERROR  078C2000   814AF356
    ILC 4  INTC 10
        256                NO ACTIVE MODULE FOUND
        256                NAME=UNKNOWN
        256                DATA AT PSW  014AF350 - B20A2000
    1F44BF43  503AB20A
        256                GR 0: 00000000   1: 00000BD8
        256                   2: 80010080   3: 915766AA
        256                   4: 00000000   5: 0057666A
        256                   6: 1076D4C8   7: 00FC7880
        256                   8: 014B0D48   9: 00000000
        256                   A: 7F44BA18   B: 7FFFBAF8
        256                   C: 00000BE0   D: 00091330
        256                   E: 00FF1000   F: 91491098
        256              END OF SYMPTOM DUMP
     04.03.40 STC17995  FPEV9999I **** DB2 PM/PE SYMPTOM RECORD ****
     04.03.40 STC17995  FPEV9999I LVLS/OMEGAMON XE PE/PM
     04.03.40 STC17995  FPEV9999I VALU/SVCE
     04.03.40 STC17995  FPEV9999I AB/S/301
     04.03.40 STC17995  FPEV9999I AB/U/000
     04.03.40 STC17995  FPEV9999I RIDS/FPEZPMS#l
     04.03.40 STC17995  FPEV9999I RIDS/
     04.03.40 STC17995  FPEV9999I PTFS/DA  ?
     04.03.40 STC17995  FPEV9999I ADRS/
     04.03.40 STC17995  FPEV9999I PSW /070C1000 80FFAD84
     04.03.40 STC17995  FPEV9999I REGS 0-1/80000000 80301000
     04.03.40 STC17995  FPEV9999I REGS 2-3/00000B80 00000BD8
     04.03.40 STC17995  FPEV9999I REGS 4-5/008C48C8 008C3B70
     04.03.40 STC17995  FPEV9999I REGS 6-7/10F6B030 00FC7880
     04.03.40 STC17995  FPEV9999I REGS 8-9/00000001 00FFB0F8
     04.03.40 STC17995  FPEV9999I REGS A-B/00000BE0 008FEDB0
     04.03.40 STC17995  FPEV9999I REGS C-D/00000080 00000001
     04.03.40 STC17995  FPEV9999I REGS E-F/00FF1A62 00000000
     04.03.40 STC17995  IEA995I SYMPTOM DUMP OUTPUT  275
        275             SYSTEM COMPLETION CODE=301
        275              TIME=04.03.40  SEQ=61907  CPU=0080
    ASID=026D
        275              PSW AT TIME OF ERROR  070C1000   80FFAD84
    ILC 2  INTC 0D
        275                NO ACTIVE MODULE FOUND
        275                NAME=UNKNOWN
        275                DATA AT PSW  00FFAD7E - 00181610
    0A0DB219  00005820
        275                AR/GR 0: 8F9CD47A/80000000   1:
    00000000/80301000
        275                      2: 00000000/00000B80   3:
    00000000/00000BD8
        275                      4: 00000000/008C48C8   5:
    00000000/008C3B70
        275                      6: 00000000/10F6B030   7:
    00000000/00FC7880
        275                      8: 00000000/00000001   9:
    00000000/00FFB0F8
        275                      A: 00000000/00000BE0   B:
    00000000/008FEDB0
        275                      C: 00000000/00000080   D:
    00000000/00000001
        275                      E: 00000000/00FF1A62   F:
    00000001/00000000
        275              END OF SYMPTOM DUMP
    

Local fix

  • Turn off Performance Warehouse in RKD2PAR member(s)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Performance Warehouse users              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The Performance Warehouse (PWH) subtask *
    *                      load module FPEZPMS abends with code    *
    *                      S202 followed by abends with code S301  *
    *                      in a loop.                              *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    The posting of an ECB in a list of ECBs fails. The consecutive
    call to the wait macro abends because the ECB had not been
    cleared. The abend handler returns control to the same code
    segment without clearing the ECB which results in a loop of
    abends S301.
    
    PROBLEM CONCLUSION:
    The code has been corrected to check the ECB before it gets
    posted. In case of abends Performance Warehouse will stop and
    issue the already existing message FPEV5002I.
    

Problem conclusion

  • The code has been corrected to check the ECB before it gets
    posted. In case of abends Performance Warehouse will stop and
    issue the already existing message FPEV5002I.
    
    KEYWORDS : ABEND S202 S301 FPEZPMS PWH
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM76269

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-11-01

  • Closed date

    2012-12-05

  • Last modified date

    2017-06-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK90058 UK90059

Modules/Macros

  •    DGO@PC1  DGOVMSTR DGOZPC1  DGOZTEX
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK90059

       UP12/12/08 P F212

  • R511 PSY UK90058

       UP12/12/08 P F212

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: