A fix is available
APAR status
Closed as program error.
Error description
A database refresh of a HALDB that does not have a KEYSTRNG defined (uses a partition selection exit) fails when IMS Cloning Tool is updating the target IMS. The update step fails with 'GCLDCU06E DBRC failed, RC=12' and the resulting DBRC output shows an error in the INIT.PART control statement. MSGGCLDCU06E
Local fix
Add a DBRCOUT DD to the IMSDBREFRESH JCL allocated to a PDS or PDSE, RECFM=FB, LRECL=80. After the IMSDBREFRESH job abends, manually edit the DBRC control statements written to DBRCOUT and remove the KEYSTRNG parameter. Then use the control statements in a DBRC utility to update the database definition on the target IMS.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Cloning Tool V1.1 * **************************************************************** * PROBLEM DESCRIPTION: Message 'GCLDCU06E DBRC failed, RC=12' * * and the resulting DBRC output shows * * an error in the INIT.PART control * * statement. * **************************************************************** * RECOMMENDATION: * **************************************************************** A database refresh of a HALDB that does not have a KEYSTRNG defined (uses a partition selection exit) fails when IMS Cloning Tool is updating the target IMS. The update step fails with 'GCLDCU06E DBRC failed, RC=12' and the resulting DBRC output shows an error in the INIT.PART control statement.
Problem conclusion
Code has been modified to correct this problem.
Temporary fix
Comments
APAR Information
APAR number
PM73248
Reported component name
IMS CLONING TOO
Reported component ID
5655U9100
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-09-19
Closed date
2012-10-01
Last modified date
2012-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK82272
Modules/Macros
GCL00345
Fix information
Fixed component name
IMS CLONING TOO
Fixed component ID
5655U9100
Applicable component levels
R110 PSY UK82272
UP12/10/04 P F210
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY5","label":"IMS Cloning Tool"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]
Document Information
Modified date:
21 October 2020