A fix is available
APAR status
Closed as program error.
Error description
The customer in the process of upgrading from MQ V7.0.1 to V7.1. They have migrated a few of the QMGRs in their environment without issues, but the most recent upgrades have abended when starting up. The dump that they are receiving shows the following abend: . Dump Title: CSQ1,ABN=5C6-00D400AD,U=SYSOPR ,C=R3600.710.DMC -CSQICRE2,M=CSQGFRCV,LOC= CSQILPLM.CSQICRE2+00000FE2 . The change team review the docs and they can see the cause of the problem. The abend occurs when a V710 queue-manager issues a DEFINE REPLACE for a QMODEL (in this case due to command in CSQ2MSTR's CSQINP2 concatenation). All other queue-managers in the queue-sharing group are informed about the DEFINE via the group command server and read the object from DB2. However, the qmodel object in DB2 has the V710 length with MQMO.fExtend3 set. CSQ5READ has logic for detecting a V710 object and resetting fExtend3, but there is an error in the processing for QMODELS, which results in the object being changed to the V701 length but MQMO.fExtend3 is left set. This causes the subsequent 5C6-00D400AD when starting at V710. The Change Team has recreated this situation on their test systems. . NOTE: The error in the CSQ5READ is at the WMQ 7.0.1 level during fallback (backward migration). PM52894/UK76760 provides the fallback logic. . Additional keywords: MQ0710C/K
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 * * Release 0 Modification 1. * **************************************************************** * PROBLEM DESCRIPTION: Queue manager abend 5C6 reason * * 00D400AD, issued by CSQICRE2 after * * migration to V710. * **************************************************************** * RECOMMENDATION: * **************************************************************** The 5C6-00D400AD abend may occur at start up of a V710 (WebSphere MQ for z/OS Version 7 Release 1 Modification 0) queue manager and results in the queue-manager abending with CSQV086E reason 00D96001. The problem is caused when a V710 queue-manager issues a DEFINE REPLACE for a QMODEL, QLOCAL, QALIAS or QREMOTE with QSGDISP(GROUP) while other queue managers in the queue sharing group are still at V701 (WebSphere MQ for z/OS Version 7 Release 0 Modification 1). The object is stored in DB2 with a V710 length with flag fExtend3 set (indicating a V710 object size). All other queue managers in the queue sharing group are informed about the DEFINE via the group command server and the object is read from DB2 and their QSGDISP(COPY) object is replaced with a COPY object at the V701 length. However, due to an error in processing in CSQ5READ the fExtend3 flag is not reset in this new COPY. Following this, when a subsequent queue manager is migrated to V710, an abend occurs at start up.
Problem conclusion
The code has been corrected so that the fExtend3 flag does not get set when creating the COPY object. 010Y CSQ5READ CSQ7CBJ
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PM72079
Reported component name
WMQ Z/OS V7
Reported component ID
5655R3600
Reported release
100
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-09-03
Closed date
2012-11-26
Last modified date
2013-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK83721
Modules/Macros
CSQ5READ CSQ7CBJ
Fix information
Fixed component name
WMQ Z/OS V7
Fixed component ID
5655R3600
Applicable component levels
R010 PSY UK83721
UP13/01/16 P F301 «
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: