APAR status
Closed as program error.
Error description
SA does not allow to move an this particular association line. When the user try to move it the mouse pointer turns to 'not allowed' and it does not let to reposition the line. To align vertically is not possible.
Local fix
Problem summary
The Class diagram in question appears to be quite unusual, which likely stems from it being created by copy-and-paste. "Unusual" means that the diagram in its current state appears to violate various methodology rules. It is unlikely that the client would be able to start a brand new Class diagram from scratch and draw an identical version without resorting to copy-and-paste.
Problem conclusion
What's going on when the user attempts to shift the position of the problem Association line is that SA runs a quick test for methodology violations and in fact finds two. However, neither of the two violations concern the line being worked on. Instead, the violations concern two other lines named "requires" and "dependencies". The client can fix the problem by deleting the two problem lines and then redrawing them. After that, he should be able to perform the shift he desires.
Temporary fix
The problem Association line is OK as-is. Instead delete and redraw two other Associaltion lines that currently violate methodology rules.
Comments
APAR Information
APAR number
PM71513
Reported component name
TLOGIC SYS ARCH
Reported component ID
5724V68SA
Reported release
B40
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-08-24
Closed date
2013-10-17
Last modified date
2013-10-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC SYS ARCH
Fixed component ID
5724V68SA
Applicable component levels
RB41 PSY
UP
RB42 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS6RBX","label":"Rational System Architect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.4","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]