A fix is available
APAR status
Closed as new function.
Error description
Support JCL generation of an Online Reorg Facility (ORF) database reorganization job for HISAM and SHISAM database types. - Additional problem also addressed: MSGIEC130I DYNLIB DD STATEMENT MISSING during step Collect/update database data set data, after DB(s) are selected on panel IDLSMAIR. This problem occurs when the DYNLIB dataset name is the same as RESLIB.
Local fix
In this case modifying the JCL generator IDLGNJCX (ReXX source) statement beginning at line 2678 to read: "if INDXTYPE < 'PRIMARY' & PRDBDIND = '1' & savedbd ¬= DBD then".. . allowed the generation of correct JCL
Problem summary
**************************************************************** * USERS AFFECTED: Users who want to build Online Reorg * * Facility (ORF) jobs for IMS HISAM and * * SHISAM databases. * **************************************************************** * PROBLEM DESCRIPTION: Incomplete JCL was generated for ORF * * jobs for IMS HISAM and SHISAM * * databases. * **************************************************************** * RECOMMENDATION: * **************************************************************** Control Suite had a builtin restriction to not build ORF jobs for IMS HISAM and SHISAM databases. This APAR removes the restriction.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PM71345
Reported component name
IMS DB CNTL SUI
Reported component ID
5655F7600
Reported release
320
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-08-22
Closed date
2012-10-09
Last modified date
2012-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK82484
Modules/Macros
IDLC0001 IDLC50 IDLGNJCC IDLGNJCX IDLIPR01 IDLIPR07 IDLIPR08 IDLSMAI2
Fix information
Fixed component name
IMS DB CNTL SUI
Fixed component ID
5655F7600
Applicable component levels
R320 PSY UK82484
UP12/10/11 P F210
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.