  • This apar addresses the following problems:
    1. New ROUTE command to allow a datastore to be logically
    suspended and resumed.  Requirement MR0326125250 is now met.
    2. The CEX print utility CEXDFPRT contains field TSKID=N/A
    and the Event Key field is incorrect.
    3. The ISPF dialog and batch utilities do not support a
    transaction beginning with a numeric character. INVALID NAME is
    received.  This is a valid transaction code that should be
    allowed.
    4. An ABEND0C4 can occur in CEXRCDPR if the recorder
    trace record is for Sync callout. The event record 161 has been
    built with an invalid application data section by CEXRCDUT
    during the conversion process.
    5. An ABEND0C1 can occur if the journal manager abends and
    CEX shuts down processing. MSGCEX5045I Connect
    Extensions task, JRNLMGR, has ended before shutdown is seen
    in CEXPRINT. CEXTECL is the abending module, R15=0
    Summary of changes
    1. The new ROUTE command will allow a user to logically
    suspend and resume activity for a datastore.
    2. Corrected the print utility to correctly format the TSKID
    and EVENT KEY fields
    3. Corrected the ISPF dialog and batch utilities to allow
    resource names to begin with a numeric character conforming to
    the IMS naming rules.
    4. Corrected CEXRCDUT to recognize the sync callout message
    that has a 4 byte application LL instead of the normal 2
    byte application LL.
    5. Changed CEXTECL to correctly check for journal abend
    and that the collect TDB is no longer available.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extentions V2.3         *
    ****************************************************************
    * PROBLEM DESCRIPTION: The CEX print utility output contains   *
    *                      N/A in the TSKID field and the event    *
    *                      Key is incorrect.                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR addresses the following issues:
    1.New ROUTE command to allow a datastore to be logically
    suspended and resumed.
    2.The CEX print utility output contains N/A in the TSKID field
    and the event Key is incorrect.
    3.The ISPF dialog and batch utilities do not support a
    transaction beginning with a numeric character. This is a valid
    transaction code that should be allowed.
    4.An Abend 0C4 can occur in CEXRCDPR if the recorder trace
    record is for Sync callout. The event record 161 has been built
    with an invalid application data section by CEXRCDUT during the
    conversion process.
    5.An 0C1 can occur if the journal manager abends and CEX shuts
    down processing. Message CEX5045I Connect Extensions task,
    JRNLMGR, has ended before shutdown is seen in CEXPRINT. CEXTECL
    is the abending module, R15=0
    6. HWSMSCX0 and HWSOTMX0 exits are automatically defined and
    loaded based on the HWSSMPL1 definition.  MSGCEX5052W will no
    longer be issued for these exits.
    

Problem conclusion

  • The following changes have been made for the above issues:
    1.The new ROUTE command will allow a user to logically suspend
    and resume activity for a datastore.
    For the AUTORESUME feature to work correctly an IMS Connect APAR
    is required to correct events 16 and 17.
    The IMS Connect V11 APAR for this service is PM70277.
    Until the required IMS Connect Service is installed, message
    CEX5125I is issued during IMS Connect initialization
    indicating that the required IMS Connect maintenance to
    support the AUTORESUME feature is not installed.
    2.Corrected the print utility to correctly format the TSKID and
    EVENT KEY fields
    3.Corrected the ISPF dialog and batch utilities to allow
    resource names to begin with a numeric character confirming
    to the IMS naming rules.
    4.Corrected CEXRCDUT to recognize the sync callout message that
    has a 4 byte application LL instead of the normal 2 byte
    application LL.
    5.Changed CEXTECL to correctly check for journal abend and that
    the collect TDB is no longer available.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM69452

  • Reported component name

    IMS CONNECT EXT

  • Reported component ID

    5655K4800

  • Reported release

    230

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-07-23

  • Closed date

    2012-10-05

  • Last modified date

    2012-12-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK82376

Modules/Macros

  • CEX#COMM CEX#MDSA CEX#MDS1 CEX#MDS2 CEX#MDS3
    CEX#MDS4 CEX#MDS5 CEX#MDS6 CEX#MDS7 CEX#MDS8 CEX#MDS9 CEX#SMAP
    CEXAGDEP CEXALDEP CEXBCMD  CEXBCMD0 CEXBCMD1 CEXBDSI0 CEXBDSI1
    CEXBDSO1 CEXBDST0 CEXCDSTP CEXCLEAN CEXCMDT  CEXCOMM  CEXCOMMP
    CEXCONS  CEXCONSC CEXCONSS CEXCREFP CEXCSETP CEXC00   CEXDDDEP
    CEXDFAFL CEXDFAPP CEXDFDRV CEXDFDS  CEXDFDSG CEXDFEX  CEXDFGRP
    CEXDFNWP CEXDFORL CEXDFORT CEXDFPRF CEXDFPSB CEXDFRTL CEXDFTXN
    CEXD02   CEXEDSTP CEXEFW   CEXEPR   CEXEVTPR CEXEXRTR CEXE05
    CEXE08   CEXFUNCM CEXGRDEP CEXGUIW  CEXINTST CEXLGDRV CEXMAIN
    CEXMSGCM CEXMSGT  CEXOLDEP CEXOPDRV CEXOPSSP CEXORDEP CEXOTDEP
    CEXPRSR  CEXPUBSP CEXPUDRV CEXRCDUT CEXREAD  CEXRHWS  CEXRLDEP
    CEXRSNT  CEXRTDEP CEXSAPCP CEXSBLKF CEXSHELL CEXSMAP3 CEXSMAP6
    CEXSMSPN CEXSTPCP CEXTECL  CEXTPLST CEXTPXML CEXTRDEP CEXTRSCP
    CEXVDEF  CEXVTXN
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R230 PSY UK82376

       UP12/10/10 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.3.0"}]

Document Information

Modified date:
22 October 2020