Error description
After RRS failure, application thread (WMB in this case) didn't become INDOUBT even though it terminated at between commit ph1 and ph2 (the thread completed ph1 prepare process and don't start ph2 commit process yet). Next, RRS restarted but resync process didn't take place. After that, we restarted QMGR, then the thread was detected as INDOUBT. This caused the thread remains as INDOUBT unless RRS is recycled again.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 * * Release 0 Modification 1 and Release 1 * * Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: Indoubt tasks remain indoubt following * * RRS failure, and require the queue * * manager to be restarted to resolve. * **************************************************************** * RECOMMENDATION: * **************************************************************** While an RRSBATCH application is performing Phase 1 Commit, an RRS failure occurs. The UR being committed is logged as indoubt by MQ, however the RRS failure prevents the UR being recorded as indoubt in RRS. When RRS restarts CSQ3RRSR is called to resync with RRS, however as RRS has no knowledge of the indoubt UR, MQ does not process it. The UR remains indoubt until the queue manager is restarted, at which point it is backed out.
Problem conclusion
CSQ3RRSR is changed to backout any indoubt RRS UR's which are not known about by RRS. 010Y 100Y CSQARIB CSQ3RRSR CSQ3RRSX
Temporary fix
Comments
APAR Information
APAR number
PM68485
Reported component name
WMQ Z/OS V7
Reported component ID
5655R3600
Reported release
010
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-07-10
Closed date
2012-12-18
Last modified date
2013-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK90470 UK90471
Modules/Macros
CSQARIB CSQ3RRSR CSQ3RRSX
Fix information
Fixed component name
WMQ Z/OS V7
Fixed component ID
5655R3600
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
04 March 2013