Error description

  • Support for Future Enhancements
    *
    This APAR also addresses an exposure that may cause S0C4-4
    abends in LOGREC, generated from the home asid of the CQM Master
    Address Space when a DB2 subsystem being monitored by Query
    monitor is not running or is stopped while being monitored.
    
    If this condition occurs, customers should stop the CQM
    collector started task and remove the affected DB2 ssid from the
    MONITOR parameter in the CQMPARMS file for the collector started
    task, then restart the collector task. The affected DB2 ssid can
    then be dynamically added to CQM's monitored list at a later
    time using option "6. Work with Monitoring Agents" on the ISPF
    client interface. However, please note that if the DB2 ssid is
    shut down or the customer decides to not monitor it, then CQM
    should be recycled again and this procedure repeated if the S0C4
    abends are being generated.
    ADDITIONAL SYMPTOMS
    ABENDS0C4 in module SRBMSCLN
    SRBMSCLN is a Query Monitor program scheduled by various Query
    Monitor programs to run in SRB mode. The S0C4 occurred in
    SRBMSCLN due to an invalid SDA address
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Support for Future Enhancements. This   *
    *                      APAR also addresses an exposure that    *
    *                      may cause S0C4-4 abends in LOGREC,      *
    *                      generated from the home asid of the     *
    *                      CQM Master Address Space when a DB2     *
    *                      subsystem being monitored by Query      *
    *                      monitor is not running or is stopped    *
    *                      while being monitored. If this          *
    *                      condition occurs, customers should stop *
    *                      the CQM collector started task and      *
    *                      remove the affected DB2 ssid from the   *
    *                      MONITOR parameter in the CQMPARMS file  *
    *                      for the collector started task, then    *
    *                      restart the collector task. The         *
    *                      affected DB2 ssid can then be           *
    *                      dynamically added to CQM's monitored    *
    *                      list at a later time using option "6.   *
    *                      Work with Monitoring Agents" on the     *
    *                      ISPF client interface. However, please  *
    *                      note that if the DB2 ssid is shut down  *
    *                      or the customer decides to not monitor  *
    *                      it, then CQM should be recycled again   *
    *                      and this procedure repeated if the      *
    *                      S0C4 abends are being generated.        *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

Temporary fix

Comments

  • APPLY the PTF.
    

APAR Information

  • APAR number

    PM65505

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-05-24

  • Closed date

    2012-10-02

  • Last modified date

    2015-01-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK82293

Modules/Macros

  •    CQM$ABND CQM$ACES CQM#ALSX CQM#ARCX CQM#BCMX
    CQM#CCSD CQM#CIDC CQM#COMX CQM#CQMA CQM#CQMC CQM#CQMD CQM#CQMI
    CQM#CQML CQM#CQMR CQM#CQMT CQM#CQM0 CQM#CQ31 CQM#CQ32 CQM#CTLF
    CQM#DRVX CQM#DSPX CQM#EXCP CQM#FDSN CQM#GPRF CQM#INIX CQM#INTX
    CQM#IVCV CQM#IVSM CQM#LCSD CQM#LCSX CQM#LOAX CQM#LOGX CQM#MAIN
    CQM#MSIN CQM#MSLC CQM#MSSN CQM#MSSP CQM#MSTB CQM#PARM CQM#PCIQ
    CQM#PCIX CQM#PCMX CQM#RCVX CQM#RESM CQM#REST CQM#RS1X CQM#RS2X
    CQM#RS3X CQM#RS4X CQM#RS5X CQM#RS6X CQM#SCLV CQM#SDIR CQM#SDMP
    CQM#SSCT CQM#SSDM CQM#SSMN CQM#STAB CQM#STLB CQM#SVPX CQM#SWTX
    CQM#SYSP CQM#UINX CQM#WDMX CQM#XQMX CQM@CCAF CQM@TBL8 CQMISMAX
    CQMISMPX CQMISMSX CQMLLOGX CQMMABA1 CQMMAB81 CQMMAB91 CQMMALOX
    CQMMALRX CQMMAUDX CQMMCALX CQMMCLA1 CQMMCLOX CQMMCL81 CQMMCL91
    CQMMCMA1 CQMMCMDX CQMMCMOX CQMMCMXX CQMMCM81 CQMMCM91 CQMMCOA1
    CQMMCO81 CQMMCO91 CQMMCRA1 CQMMCR81 CQMMCR91 CQMMC2A1 CQMMC281
    CQMMC291 CQMMEACX CQMMEAPX CQMMEARX CQMMEASX CQMMEMTX CQMMESA1
    CQMMESQX CQMMES81 CQMMES91 CQMMEXCX CQMMEXXX CQMME8CX CQMME8PX
    CQMME8RX CQMME8SX CQMME9CX CQMME9PX CQMME9RX CQMME9SX CQMMFREX
    CQMMFRX1 CQMMGNMX CQMMHSTX CQMMHSX9 CQMMINDX CQMMINIX CQMMINST
    CQMMLCA1 CQMMLC81 CQMMLC91 CQMMLRA1 CQMMLR81 CQMMLR91 CQMMMETX
    CQMMMFRR CQMMPRA1 CQMMPR81 CQMMPR91 CQMMRRA1 CQMMRR81 CQMMRR91
    CQMMSACX CQMMSAPX CQMMSARX CQMMSASX CQMMSCLX CQMMSQA1 CQMMSQLX
    CQMMSQ81 CQMMSQ91 CQMMSRA1 CQMMSRCX CQMMSRVX CQMMSR81 CQMMSR91
    CQMMSSQX CQMMSTRX CQMMS8CX CQMMS8PX CQMMS8RX CQMMS8SX CQMMS9CX
    CQMMS9PX CQMMS9RX CQMMS9SX CQMMTPA1 CQMMTP81 CQMMTP91 CQMMT1A1
    CQMMT181 CQMMT191 CQMMT2A1 CQMMT281 CQMMT291 CQMOINIX CQMOINST
    CQMOREDX CQMOXGAX CQMOXG8X CQMOXG9X CQMPARSE CQMPCR1X CQMTEDA1
    CQMTED81 CQMTED91 CQMTTEX1 CQMTTXTX CQMTXLA1 CQMTXL81 CQMTXL91
    CQMWTOMX H238310J
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R310 PSY UK82293

       UP12/10/15 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.