A fix is available
APAR status
Closed as program error.
Error description
Depending on SMP/E LMOD Return code (RC) settings, the user can see failure of APPLY of UK77499 due to the linkedit error: IEW2315E 1369 IDENTIFY DATA COULD NOT BE ADDED TO DSQIELI BECAUSE THE SECTION DOES NOT EXIST. For users who have applied the PTF successfully, the error does not prevent QMF from running and does not cause any runtime issues. MSGGIM23901E MSGGIM23901 GIM23901E GIM23901 PM55683
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All QMF for TSO/CICS V10.1 users. * **************************************************************** * PROBLEM DESCRIPTION: Users applying QMF PTF UK77499 will * * receive link-edit error message: * * MSGIEW2315E 1369 'IDENTIFY DATA * * COULD NOT BE ADDED TO DSQIELI BECAUSE * * THE SECTION DOES NOT EXIST.' This * * could cause the SMP/E APPLY job to * * end with a condition code 8. The job * * condition code depends on the SMP/E * * maximum allowable return code set in * * the SMP/E zone. MSGGIM23901E can be * * seen for various modules. * **************************************************************** * RECOMMENDATION: * **************************************************************** QMF PTF UK77499 was improperly built. It included an IDENTIFY statement for module DSQIELI which should not have been present. Users who successfully applied UK77499 should not encounter errors in the runtime product.
Problem conclusion
The IDENTIFY statement for module DSQIELI has been removed.
Temporary fix
Comments
APAR Information
APAR number
PM63280
Reported component name
QMF-QUERY MGMT
Reported component ID
566872101
Reported release
A10
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-04-25
Closed date
2012-04-26
Last modified date
2012-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK78288
Modules/Macros
DSQIELI
Fix information
Fixed component name
QMF-QUERY MGMT
Fixed component ID
566872101
Applicable component levels
RA10 PSY UK78288
UP12/04/27 P F204
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]