Error description

  • This APAR allows OPC and OER to:
    1) Run a fast scan of database integrity and produce the
       free space analysis reports in one step when TYPRUN=FS and
       FULLSTEP=YES are specified.
    2) Store sensor data in IMS Tools KB Sensor Data Repository
       when SENSOR=YES is specified & TYPRUN=MODEL isn't specified.
       Now sensor data can be stored only when SENSOR=YES,
       TYPRUN=RPT and FULLSTEP=YES are specified.
    3) Provide a mapping macro of the history2 file, named HFPAMHS2,
       in *.SHFPMAC0.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Online Pointer Checker and Online Expert *
    *                 Reorganization users of HPFPU Fast Path      *
    *                 Online Tools in Fast Path Solution Pack      *
    *                 Version 1 Release 2 (FMID: HAHQ120).         *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR supports the following        *
    *                      new functions:                          *
    *                                                              *
    *                       1. OPC and OER store sensor data with  *
    *                          TYPRUN=PTRSCAN/PTRALL/FS processing *
    *                            mode.                             *
    *                                                              *
    *                       2. OPC and OER generate the FREE SPACE *
    *                          ANALYSIS REPORTS when TYPRUN=FS and *
    *                          FULLSTEP=YES are specified.         *
    *                                                              *
    *                       3. The HFPAMHS2 marco is provided for  *
    *                          mapping History2 data set record.   *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    1. OPC and OER store sensor data in IMS Tools KB Sensor Data
       Repository when following conditions are met:
       1. SENSOR=YES, and TYPRUN=PTRSCAN/PTRALL/FS/RPT are
          specified.
       2. ITKBSRVR is specified correctly.
       3. ITKB product library is specified at STEPLIB DD.
       4. PTRCHK=YES and CHKUOW=ALL is specified (for OER only).
    
    2. OPC and OER generate the FREE SPACE ANALYSIS REPORTS, and
       output the reorganization control statements for the
       High-Speed DEDB Direct Reorganization utility (DBFUHDR0)
       in a data set when TYPRUN=FS and FULLSTEP=YES are specified.
    
    3. The HFPAMHS2 marco is provided for mapping History2 data set
       record.
    

Problem conclusion

Temporary fix

Comments

  • ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IMS Fast Path Solution Pack for z/OS Version 1 Release 2
    IMS High Performance Fast Path Utilities User's Guide
    (SC19-3287-00).
    
    For the documentation changes made by this APAR, see
    http://www-01.ibm.com/support/docview.wss?uid=swg27023880.
    

APAR Information

  • APAR number

    PM60111

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    120

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2012-03-09

  • Closed date

    2012-06-25

  • Last modified date

    2012-07-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK79796

Modules/Macros

  • FPXANAL0 FPXAPRCA FPXAPRCB FPXAPRCC FPXASCP0
    FPXASNC0 FPXASXT0 FPXATA00 FPXATDC0 FPXAUCS0 FPXMBLK0 FPXMSG00
    FPXPDRVA FPXPDRVB FPXPDRVC FPXSADB0 FPXUCA00 FPXUCMC0 FPXUCM00
    FPXUCOP0 FPXUCPR0 FPXUCTL0 FPXUMOD0 FPXUSNB0 FPXXRG00 HAHQ120J
    HFPQADA0 HFPQAIN0 HFPQAMA0 HFPQA1I0 HFPQA1T0 HFPQFAC0 HFPQFAD0
    HFPQFAH0 HFPQFAN0 HFPQFSN0
    

Publications Referenced
SC19328700    

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R120 PSY UK79796

       UP12/06/28 P F206

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 July 2012