A fix is available
APAR status
Closed as program error.
Error description
If you change the PICOUT or PICIN of a variable in the Design View, the BMS editor wrongly changes the LENGTH parameter. The design view field remains at the original width, but the LENGTH parameter reflects the width of the PICOUT instead of the width of the data.
Local fix
Problem summary
The value of the PICOUT as resolved was not being updated into the macro. This has been fixed.
Problem conclusion
The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.0.3.2 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PM58370
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
803
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-16
Closed date
2012-04-10
Last modified date
2012-04-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R803 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"803","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
28 October 2021