IBM Support

PM55324: FP PRINTING UTILITY ENDS UP WITH ABEND0C4 WHEN THE NUMBER OF UOW IS 32766

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FP Printing Utility ends up with ABENDS0C4 when UOW_REPORT=YES
    is specified and the total number of UOW stored in the sensor
    repository is 32766.  The abend is a PIC11 out of BSNSDSD2 at
    x'FDC'.
    Also, the wrong page number is displayed on the SENSOR DATA
    STATISTICS REPORT when the total page number is more than 32767.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool   *
    *                 in Fast Path Solution Pack Version 1         *
    *                 Release2 (FMID: HAHQ120).                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. FP Printing Utility ends up with     *
    *                      ABEND 0C4 when UOW_REPORT=YES is        *
    *                      specified and the total number of UOW   *
    *                      stored in the sensor repository is      *
    *                      32766.                                  *
    *                                                              *
    *                      2. The wrong page number is displayed   *
    *                      on the SENSOR DATA STATISTICS REPORT    *
    *                      when the total page number is more      *
    *                      than 32767.                             *
    *                                                              *
    *                      3. The prologs of the sample JCLs,      *
    *                      HFPCSITE and HFPSCTL0, include some     *
    *                      grammatical errors.                     *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    1. 0c4 Abend occurs when the following conditions are all met:
    
        A. The total number of UOW stored in the sensor repository
           is 32766. (0 32765 is working fine)
        B. UOW_REPORT=YES is specified.
    
    2. Page number is incorrect when the following conditions are
       all met:
    
        A. The total number of UOW is more than 16382.
           (Wrong numbers are displayed after page 32767)
        B. UOW_REPORT=YES is specified.
    
    3. The prologs of the sample JCLs, HFPCSITE and HFPSCTL0,
       include some grammatical errors.
    

Problem conclusion

  • 1. 0c4 Abend occurs due to the record numbers in the code
       exceeded the limit.  Changed the limit number, MAXRECNM at
       HFPSPSDS.
    
    2. Incorrect page number is displayed because max page number
       was 32767.  Changed the page number limit, RCTPAGE at
       HFPSRCT, and with this, modified variable type at HFPSRPTH.
    
    3. Modified the prologs of the sample JCLs, HFPCSITE and
       HFPSCTL0.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM55324

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-01-04

  • Closed date

    2012-01-12

  • Last modified date

    2012-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK75379

Modules/Macros

  •    HFPCSITE HFPSCTL0 HFPSPANA HFPSPPRT HFPSPRNT
    HFPSPSDS HFPSRPTH HFPSSTMP HFPSSTMS
    

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R120 PSY UK75379

       UP12/01/18 P F201

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]