A fix is available
APAR status
Closed as program error.
Error description
An image copy job built by Automation Tool with the following circumstances can result in an S413 abend when running the generated image copy job. 1). Image copies are being written to tape. 2). Templates are not being used. 3). The requested SHRLEVEL is modified for some object by Automation Tool. For example, SHRLEVEL Change is requested, but a Materialized Query Table created with LOG NO is included. This object does not support SHRLEVEL change, so Automation Tool changes the image copy for this object to SHRLEVEL REFERENCE. . The symptoms would include message IEC145I 413-08, and SYSTEM COMPLETION CODE=413 REASON CODE=00000008.
Local fix
Change the Generate Templates setting on the Job Profile to Y.
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: An image copy job built by Automation * * Tool with the following circumstances * * can result in an S413 abend when * * running the generated image copy job. * * 1. Image copies are being written to * * tape. * * 2. Templates are not being used. * * 3. The requested SHRLEVEL is modified * * for some object by Automation Tool. * * For example, SHRLEVEL Change is * * requested, but a Materialized Query * * Table created with LOG NO is included. * * This object does not support SHRLEVEL * * change, so Automation Tool changes * * the image copy for this object to * * SHRLEVEL REFERENCE. * * The symptoms would include message * * IEC145I 413-08, and SYSTEM COMPLETION * * CODE=413 REASON CODE=00000008. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PM54170
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-12-12
Closed date
2012-05-01
Last modified date
2012-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK78413
Modules/Macros
HAA$BUTC
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R410 PSY UK78413
UP12/05/04 P F205
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: