A fix is available
APAR status
Closed as new function.
Error description
This APAR will add the following new function: - Add support for IMS exit DFSBSEX0 - Add an option to reject LTERM creation The following issues will be addressed: - Correct error when using ACF2 idle terminal signoff. - Correct error when an SLU1 Console or SLUTYPEP device was added using the batch update utility (IZTUD1U0), the online transaction (IZTRAN) was receiving MSGIZT4665E.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS ETO Support V3.1 * **************************************************************** * PROBLEM DESCRIPTION: This APAR will add the following new * * function: * * Add support for IMS exit DFSBSEX0 * * Add an option to reject LTERM creation * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR will add the following new function: - Add support for IMS exit DFSBSEX0 - Add an option to reject LTERM creation The following issues will be addressed: - Correct error when using ACF2 idle terminal signoff. - Correct error when an SLU1 Console or SLUTYPEP device was added using the batch update utility (IZTUD1U0), the online transaction (IZTRAN) was receiving MSGIZT4665E.
Problem conclusion
Temporary fix
Comments
ETO Support has been updated to not reset the high order bit of register 15 unless the rest of the bits are zeros. This should correct the error with the ACF2 idle terminal timeout. IZTRAN was corrected to check for spaces and low-values in the multiple LTERM field. This corrects the error where records added using the batch update utility, and read using IZTRAN. Added the following enhancements: - Support for IMS user exit DFSBSEX0 - Ability to reject LTERM creation
APAR Information
APAR number
PM50570
Reported component name
IMS ETO SUPPORT
Reported component ID
5655E1200
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function
Submitted date
2011-10-20
Closed date
2011-12-07
Last modified date
2012-01-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK74559
Modules/Macros
H1J4310J IZTAPPC0 IZTAPPC9 IZTBSEXZ IZTCCMDA IZTCCMDB IZTCCMDC IZTCCMD7 IZTCCMD8 IZTCCMD9 IZTINSXA IZTINSXB IZTINSXC IZTINSX7 IZTINSX8 IZTINSX9 IZTINTXL IZTJLST0 IZTJUPDB IZTJUPDD IZTJUPD0 IZTLIST IZTLOAD2 IZTNUPD0 IZTRAN IZTUD1U0 IZTUMOD3
Fix information
Fixed component name
IMS ETO SUPPORT
Fixed component ID
5655E1200
Applicable component levels
R310 PSY UK74559
UP11/12/08 P F112
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX897","label":"IMS ETO Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: