IBM Support

PM50007: 0C4 AT OFFSET X'F46' IN FPEVRDS1 LOAD MODULE FPEVDB2I

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If the end-to-end SQL monitoring function (Extended Insight) is
    enabled, a 0C4 abend may occur when retrieving data from the PE
    Server instance. This will cause the monitored instance to come
    down and will need an explicit restart.
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   PE Server subtask                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: 0C4 AT OFFSET X'F46' IN FPEVRDS1 LOAD   *
    *                      MODULE FPEVDB2I                         *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF if you use the end-to-end     *
    *                 SQL Monitoring functionality (Extended       *
    *                 Insight)                                     *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    0C4 AT OFFSET X'F46' IN FPEVRDS1 LOAD MODULE FPEVDB2I
    
    PROBLEM CONCLUSION:
    The PE Server subtask code has been corrected to fix this
    problem.
    

Problem conclusion

  • The PE Server subtask code has been corrected to fix this
    problem.
    
    KEYWORDS :    EXTENDED INSIGHT E2E MONITORING, PE SERVER
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM50007

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-10-13

  • Closed date

    2011-11-18

  • Last modified date

    2011-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK73987

Modules/Macros

  • DGOVMSTR DGOVZAP  FPEVRDS1
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK73987

       UP11/11/22 P F111

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 December 2011