IBM Support

PM49524: IMAGE COPY HEADER IS BUILT INCORRECTLY FOR A PSINDEX WHEN CALLING HPIC API FROM DRF.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The Image Copy header is built incorrectly for a PSINDEX when
    calling HPIC API from DRF.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    *                 who use IMS Recovery Solution Pack for z/OS  *
    *                 Version 1 Release 1.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: HP Image Copy under IMS Database        *
    *                      Recovery Facility creates the incorrect *
    *                      image copy data set of PSINDEX database *
    *                                                              *
    *                      When the image copy data set of         *
    *                      PSINDEX is used for recovery            *
    *                      utilities, recovery process fails with  *
    *                      unexpected image copy header record.    *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HP Image Copy under IMS Database Recovery Facility creates the i
    image copy data set of PSINDEX database.
    When the image copy data set of PSINDEX is used for recovery
    utilities, recovery process fails with error message of
    unexpected image copy header record.
    
    Header record of image copy data set for PSINDEX should have fol
    information:
    - Partition name of PSINDEX database
    - DCB number should be be 1
    
    HP Image copy sets correct information by this APAR.
    

Problem conclusion

  • FABJDRQS has been modified to set the partition name and value
    of 1 as the DCB number to the image copy header record when the
    processing database is PSINDEX.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PM49524

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-10-06

  • Closed date

    2011-10-17

  • Last modified date

    2011-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK72976

Modules/Macros

  • FABJDRQS
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UK72976

       UP11/10/19 P F110 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.2.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: