IBM Support

PM47991: CKZ67121E UNABLE TO ACCEPT CONNECTION WITH PORT 5099, RETCODE=X'FFFFFFFF, ERRNO=1002

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This error occurs in the TCPIP server when more than 50 connects
    are made to the TCPIP server from the source job. The TCPIP
    error is EIBMSOCKOUTOFRANGE (the socket number assigned by the
    client interface code is out of range).
    
    KEYWORDS
    MSGCKZ67121E CKZ67121E
    

Local fix

  • Cycle the TCPIP server every 40 or so connects
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This error occurs in the TCPIP server   *
    *                      when more than 50 connects are made to  *
    *                      the TCPIP server from the source job.   *
    *                      The TCPIP error is EIBMSOCKOUTOFRANGE   *
    *                      (the socket number assigned by the      *
    *                      client interface code is out of range). *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM47991

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-09-15

  • Closed date

    2011-09-26

  • Last modified date

    2011-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK72239

Modules/Macros

  •    CKZ00501 CKZ00671
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R220 PSY UK72239

       UP11/09/30 P F109

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: