Fixes are available
APAR status
Closed as program error.
Error description
In a model Automotive_ACC_SEv3 the code that is generated for the flowports is not complete. Also, the warnings generated for flowports are inconsistent with what is showing in the model. Believe that this may be related to the use of flowports with composite classes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The model was originally built on systems designer (C++) and then reopened in RiC in order to generate code. Model was converted to C. Though on user view, all seems to be C (i.e. units), inside, some types, which reside both on PredefinedTypesC and PredefinedTypesCpp (e.h. "double") were left with the original location. There for the check find 2 "double" types, which are not being considered the same type and the check fails (and also, CG skips these).
Problem conclusion
Fixed in Scorpio
Temporary fix
Comments
APAR Information
APAR number
PM46570
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-08-28
Closed date
2012-09-21
Last modified date
2012-09-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R760 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.6","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
28 October 2021