IBM Support

PM43855: FTP TRANSFER ABORTING AFTER THE PERIOD STATED IN THE -TIMEOUT SETTING WHEN EXECUTED ON THE LINUX 64 BIT PLATFORM

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A map has the -TIMEOUT 5 option on an FTP transfer.
    
    When run on Windows, the map continues to retrieve the file
    until the end of the file is reached, even if the period of
    time taken exceeds the -TIMEOUT value.
    
    When run on a LINUX 64bit box, the map aborts after 5 seconds
    (corresponding to the -TIMEOUT 5 setting)
    
    The trace contains:
    
    WSARecvDTX: Operation has timed out.
       Timeout in seconds: 0.
    Socket Closed.
    

Local fix

  • WTXCQ - WTX00038096
    PB / PB
    Circumvention: None
    

Problem summary

  • Users Affected:
    WebSphere Transformation Extender customer using FTP adapter
    
    Problem Description:
    The FTP adapter times out when receiving large files on a Linux
    box.
    
    Platforms Affected:
    Linux
    

Problem conclusion

  • The FTP Adapter no longer times out when retrieving large files
    on a Linux box.
    
    Delivered in:
    8.1.0.6, 8.2.0.6, 8.3.0.5
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM43855

  • Reported component name

    WSTX

  • Reported component ID

    5724M4019

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-07-18

  • Closed date

    2011-09-23

  • Last modified date

    2012-01-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WSTX

  • Fixed component ID

    5724M4019

Applicable component levels

  • R810 PSY

       UP

  • R820 PSY

       UP

  • R830 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
17 January 2012