A fix is available
APAR status
Closed as program error.
Error description
Dump Title: OMEGAMON II FOR DB2: COMPID=5655W3700, LMOD=KO2CDBCB#L, CSECT=#UNKNOWN, OFFSET=025CA0 ABENDS0C4-11 in KO2CSTBB+6D8 at PM32638 level. DUMP TITLE=OMEGAMON II FOR DB2: COMPID=5655W3700, LMOD=KO2CDBCB#L, CSECT=#UNKNOWN, OFFSET=018BE0 ABENDS0C4-4 in KO2CSTBB+6DE (KO2CSTBB+6DA) at PM32638 level. Program KO2CSTBB is moving beyond it's allocated storage. Could also cause messages. KO2O1315W NEAR-TERM HISTORY DATA COLLECTOR - INVALID OUTPUT RECEIVED RECOVERY KO2Z999E OMPE V510 Service Error XSM=KO2ZXPCB/ZSHIFT ABEND=U2008 RSN=00000000 MODE=ABEND KO2O1310I NEAR-TERM HISTORY DATA COLLECTOR SERVER KO2DMGRB xxxx HAS TERMINATED (SVESTAE )
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OMEGAMON Collector * * - Classic Interface * * - CUA Interface * **************************************************************** * PROBLEM DESCRIPTION: ABENDS0C4 RC11 IN * * MODULE KO2CSTBB+X'6D8' CAUSED BY * * OVERLAY OF OMEGAMON DB2 STORAGE. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Program KO2CSTBB moving data beyond allocated memory area. Extra Statistics records were moved to data area. PROBLEM CONCLUSION: Change Near Term History Collector to only collect Statistics IFCIDs on the Collection Interval. Correct limit on data moves by program KO2CSTBB.
Problem conclusion
Change Near Term History Collector to only collect Statistics IFCIDs on the Collection Interval. Correct limit on data moves by program KO2CSTBB.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PM43756
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2011-07-14
Closed date
2011-09-28
Last modified date
2011-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DUMM3KO2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
03 October 2011