Error description
This APAR will address the following issues: - The console and sysout can be flooded with MSGCEX5019I when the local adapter is being used. - Correct the situation where a WAS local Client disconnect is followed by a local client connect causes the ICON joblog to be flooded with MSGCEX2019I.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extentions V2.2 * **************************************************************** * PROBLEM DESCRIPTION: The console and sysout can be flooded * * with message CEX5019I when the local * * adapter is being used. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR will address the following issues: 1. The console and sysout can be flooded with message CEX5019I when the local adapter is being used. 2. The OTMA trace record x'A3' for message exit called has incorrect application data when the application data has an LLLL format such as used with sync callout. The application data may show only the LL portion of the LLLL field in the application data and the last two bytes of application data are incorrect. 3. Field CERE_62_CX1_RSN can contain a value of x'00000001' when CERE_62_CX1_RC contains a value of x'00000000'. The RSN value is incorrect. 4. The OTMA security section in the x'A3' event record is always x'68' bytes long even if the OTMA Security header section is shorter than x'6A'. This causes the security section in the event record to contain data collected from the OTMA User section as if it was the UTOKN field of the security data. 5. The RXML trace record x'A9' may be 2 bytes shorter than it should be. This can cause overlay of the STCK time field. 6. The CERE_A9_CONT flag does not contain the CERE_A9_CO_RXML flag when the RXML trace event is created. 7. ISPF dialog Operations main panel shows all ICONs as INACT if TSO user's OMVS segment not defined correctly.
Problem conclusion
The following changes have been made for the above issues: 1. Correct the situation where a WAS local Client disconnect is followed by a local client connect causes the ICON joblog to be flooded with message CEX2019I. 2. Corrected module CEXTECL to correctly format the application data section for trace records that use the LLLL format indicated by CERE_A3_CODE = x'06'. 3. Corrected module CEXEXRTR to not incorrectly set the message exit parmlist RSN code field with a value of x'00000001' 4. Changed CEXTECL to honor the length of the current OTMA security section when building the event x'A3' security section and include only the sections that are present 5. Corrected CEXTECL to record the correct length for the RXML trace event record. 6. Corrected CEXTECL to set the CERE_A9_CO_RXML flag properly. 7. Changed ISPF dialog to not allow user to navigate to Operations panel if OMVS segment is not defined correctly for user. User Action: 1. SMP/E Receive and Apply the fix. 2. Restart your IMS Connect Extensions system.
Temporary fix
Comments
APAR Information
APAR number
PM43558
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-07-12
Closed date
2011-08-12
Last modified date
2011-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
010PC2 UK70790 010PC2
Modules/Macros
CEXAPMT1 CEXCR56 CEXCR57 CEXDFDRV CEXEVTPR CEXEVT01 CEXEVWTR CEXEXRTR CEXE08 CEXOPDRV CEXPRED0 CEXPRED1 CEXPUBMN CEXRCDPR CEXRCDUT CEXR163 CEXSALUT CEXSQPWP CEXTECL
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R220 PSY UK70790
UP11/08/16 P F108
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]
Document Information
Modified date:
22 October 2020