IBM Support

PM40579: BATCH WSL SYSPRINT DSN NOT RETRIEVED FROM ADB2UCUS. FFA10 PM36340.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • BATCH WSL SYSPRINT DSN NOT RETRIEVED FROM ADB2UCUS
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the DB2 Administration Tool for     *
    *                 z/OS Version 7.2 who use SAMP member         *
    *                 member ADB2UCU6 to update skeleton           *
    *                 ADB2UCUS. Users of the DB2 Administration    *
    *                 Tool for z/OS Version 10.1 who will need to  *
    *                 use ADB2UCU4, which is provided via this     *
    *                 APAR.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: In the DB2 Administration Tool for      *
    *                      z/OS, while running a Work Statement    *
    *                      List (WSL) using batch job, the         *
    *                      SYSPRINT DSN for the ADBTEP2 step       *
    *                      is missing and fails with the following *
    *                      JCL error:                              *
    *                                                              *
    *                      IEF648I INVALID DISP FIELD- PASS        *
    *                      SUBSTITUTED                             *
    *                                                              *
    *                      and the ADBWSPR DSN is also missing and *
    *                      fails with the following error:         *
    *                                                              *
    *                      IEF212I ADBWSPR - DATA SET NOT FOUND    *
    *                                     STEP WAS NOT EXECUTED.   *
    *                                                              *
    *                      As a result, the Load Summary Report    *
    *                      step is not retrieved from the          *
    *                      ADB2UCUS ISPF skeleton. The data sets   *
    *                      are allocated using the TSO userid      *
    *                      as the high level qualifier which       *
    *                      might not be workable for the user.     *
    *                      APAR PM08490 has already enabled        *
    *                      retrieving customized SYSPRINT DSN      *
    *                      from ADB2UCUS but missed the SAMPLE     *
    *                      job and the ++HOLD DATA describing      *
    *                      post-SMP/e customization steps.         *
    *                      Also, the prefix of data sets from      *
    *                      DB2 Object Compare/Change               *
    *                      Management panel GOC5 ' Generate        *
    *                      Compare Jobs' and panel ADB2CEX1        *
    *                      'Run a Change' is not applied to        *
    *                      WSL SYSPRINT DSN when the user          *
    *                      choose to build the RUN WSL JCL         *
    *                      during the COMPARE or ANALYZE           *
    *                      change.                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    In the DB2 Administration Tool for z/OS, while running a Work
    Statement List (WSL) using batch job, the SYSPRINT DSN for the
    ADBTEP2 step is missing and fails with the following JCL error:
    
    IEF648I INVALID DISP FIELD- PASS SUBSTITUTED
    
    and the ADBWSPR DSN is also missing and fails with the
    following error:
    
    IEF212I ADBWSPR - DATA SET NOT FOUND
                   STEP WAS NOT EXECUTED
    
    As a result, the Load Summary Report step is not retrieved from
    the ADB2UCUS ISPF skeleton.  The data sets are allocated using
    the TSO userid as the high level qualifier which might not be
    workable for the user.  APAR PM08490 has already enabled
    retrieving customized SYSPRINT DSN from ADB2UCUS but missed the
    SAMPLE retrieving customized SYSPRINT DSN from ADB2UCUS but
    missed the SAMPLE job and the ++HOLD DATA describing post-SMP/e
    customization steps.  DB2 Object Compare/Change Management
    panel GOC5 ' Generate Compare Jobs' and panel ADB2CEX1 'Run
    a Change' is not applied to WSL SYSPRINT DSN when the user
    choose to build the RUN WSL JCL during the COMPARE or
    ANALYZE change.
    

Problem conclusion

  • Sample member ADB2UCU6 for DB2 Administration Tool for z/OS
    Version 7.2 and ADB2UCU4 for DB2 Administration Tool for z/OS
    Version 10.1 were added to provide the instructions on the
    post-SMP/e customization steps.  Skeleton ADB2WL4 was modified
    by removing the building of the &PRINTDSN value let the value
    be retrieved from ADB2UCUS.  This APAR also enables the prefix
    of data sets from DB2 Object Compare/Change Management panels
    GOC5 'Generate Compare Jobs' and panel ADB2CEX1 'Run a Change'
    to be applied to &PRINTDSN when a user choose to be build the
    run WSL JCL during a COMPARE or ANALYZE change.
    
    After this APAR is applied, the user must perform the action
    described in the ++HOLD. If the instructions in ++HOLD is not
    followed, the &PRINTDSN will be blank, and running WSL in
    batch mode will fail with a JCL error due to a missing value
    for SYSPRINT DSN.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM40579

  • Reported component name

    DB2 OBJECT COMP

  • Reported component ID

    5697G6400

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-06-01

  • Closed date

    2011-06-27

  • Last modified date

    2011-07-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    GOCGCMP
    

Fix information

  • Fixed component name

    DB2 OBJECT COMP

  • Fixed component ID

    5697G6400

Applicable component levels

  • RA10 PSY UK69175

       UP11/06/30 P F106

  • R720 PSY UK69176

       UP11/06/30 P F106

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021