IBM Support

PM35052: After UK65412 SMP/E ACCEPT fails with IEW2230S and BIND fails for EXPLAIN function with inconsistent DBRM

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 1. SMP/E SMPE ACCEPT check is successful for UK65412 but actual
    ACCEPT fails for object KO2ZZCC
    IEW2322I 1220 1 INCLUDE SMPWRK3(KO2ZZCC) UK65325 SEQ # 0
    IEW2322I 1220 2 SETSSI 01115325
    IEW2322I 1220 3 NAME KO2ZZCC(R) MAX ACCEPTABLE RC=08
    IEW2230S 0414 MODULE HAS NO TEXT.
    IEW2650I 5102 MODULE ENTRY NOT PROVIDED. ENTRY DEFAULTS TO
    SECTION OMPEZCC.
    IEW2008I 0F03 PROCESSING COMPLETED. RETURN CODE = 12.
    
    2. BIND fails for EXPLAIN component, EXPLAIN is unavailable
    DSNT231I  -QSSA BIND DBRM ERROR
    USING IS6X AUTHORITY
    PACKAGE=HAMBURG_QSSA.KO2EX510.DGO@TPL3
    DBRM DGO@TPL3 IS IN AN INCONSISTENT STATE
    
    DSNT231I  -QSSA BIND DBRM ERROR
    USING IS6X AUTHORITY
    PACKAGE=HAMBURG_QSSA.KO2EX510.DGO@TPL4
    DBRM DGO@TPL4 IS IN AN INCONSISTENT STATE
    
    
    This effects the following APAR / PTF => PEing APAR combinations
    PM24083 / UK65325 => PM35049
    PM32638 / UK65399 => PM35051
    PM32647 / UK65412 => PM35052
    

Local fix

  • 1. Do not ACCEPT UK65412
    2. n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   OMEGAMON collector                       *
    *                 -   PE Server subtask                        *
    *                 -   The component that transfers DB2         *
    *                     monitoring data collected by the         *
    *                     OMEGAMON collector to the TEMA           *
    *                 -   Classic Interface                        *
    *                 -   CUA Interface                            *
    *                 -   Performance Expert Client                *
    *                 -   EXPLAIN                                  *
    *                 -   ICAT                                     *
    *                 -   Batch Reporting                          *
    *                 -   Performance Database users               *
    *                 -   Performance Warehouse users              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Collection of new functionality and     *
    *                      development fixes/enhancements.         *
    *                                                              *
    *                      In addition this PTF solves an SMP/E    *
    *                      ACCEPT issue and a BIND EXPLAIN issue.  *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    See Problem Conclusion of PM35049
    
    PROBLEM CONCLUSION:
    See Problem Conclusion of PM35049
    

Problem conclusion

  • See Problem Conclusion of PM35049
    
    New versions for the following books are available on the
    DB2 Tools Library Page:
    
    http://www.ibm.com/software/data/db2imstools
    /db2tools-library.html#omegaxepe-lib
    
    (SH12-6927-01) Reporting User's Guide
    (SH12-6921-01) Report Reference
    (SH12-6924-01) Monitoring Performance from the
                   OMEGAMON Classic Interface
    
    There are also TechDocs available for the following books.
    To access the TechDoc content for the specific book click on
    the link titled 'See updates to this Book!' for the
    corresponding book entry.
    
    (GH12-6928-00) Configuration and Customization
    (GH12-6923-00) Messages
    
    
    KEYWORDS : SMP/E ACCEPT BIND EXPLAIN
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PM35052

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-03-17

  • Closed date

    2011-03-18

  • Last modified date

    2017-06-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK65933

Modules/Macros

  •    DGO@TPL3 DGO@TPL4 DGOYTPL3 DGOYTPL4
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK65933

       UP11/03/24 P F103 «

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
16 June 2017