APAR status
Closed as program error.
Error description
The version 7 runtime jar throws the EGL0147E if the maximum amount of data we'd pass on a call to CICS is over 32500 bytes although the linkage included luwControl = SERVER (The version 6 runtime jar allows upto 32,659 bytes).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** A Java wrapper generated from version 6, which passes more than 32,500 bytes to a CICS program, does not work when used with the version 7 runtime jars. Error EGL0147E is given.
Problem conclusion
The runtime jar now allows up to 32,659 bytes for calls if the linkage doesn't include luwControl = SERVER. When the linkage says luwControl = CLIENT, only 32,500 bytes can be passed on the call.
Temporary fix
Comments
APAR Information
APAR number
PM34713
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-03-14
Closed date
2011-05-06
Last modified date
2011-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R751 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: