A fix is available
APAR status
Closed as program error.
Error description
Description of problem: RAD is consuming over 37% CPU continually when Memory Monitor is enabled Environment: - Windows XP (x86) SP3 - RAD/RSA 7.5.5.3 - Product name (Build ID or version/patch level) Step to reproduce: - Create a new workspace - Enable Memory Monitor and set the Poll interval to 15 (Windows > Preferences > General > Performance Monitors > Memory Monitor) - Restart RAD and monitor the CPU usage. Is will stick around 37% Workaround: - Go to Windows > Preferences > General > Performance Monitors > Memory Monitor and change Poll interval to a different value and click apply. - Change the value back to the previous value and again click apply. The CPU usage will drop.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** If the Memory Monitor is enabled via the preference page General ? Performance Monitors ? Memory Monitor then the next time the product is started it will consume unnecessary CPU cycles as it is monitoring, by default, every 15 milliseconds.
Problem conclusion
The default memory monitor interval has been corrected to monitor every 15 seconds. The fix for this problem is included in Rational Application Developer version 7.5.5.4 and 8.0.2.
Temporary fix
Comments
APAR Information
APAR number
PM33515
Reported component name
SW ARCHITECT WI
Reported component ID
5724I7001
Reported release
755
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-02-24
Closed date
2011-06-30
Last modified date
2011-06-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL APP DEV WI
Fixed component ID
5724J1901
Applicable component levels
R755 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSRTLW","label":"Rational Application Developer for WebSphere Software"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.5","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]