IBM Support

PM25895: ABENDS0C4 RC04 IN FPEVDB2I MODULE CAUSED BY TIMEOUT IN DB2

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer received the following error:
    FPEV0560E  RA3F DB2 RETURNED INCORRECT DATA REQUEST CANCELED
    FPEV9999I VALU/PCHK
    FPEV9999I AB/S/0C4                                            .
    FPEV9999I AB/U/000
    FPEV9999I RIDS/FPEVDB2I#l
    FPEV9999I RIDS/DGOVMRAS
    FPEV9999I PTFS/ 2008.182 V4
    FPEV9999I ADRS/010E
    FPEV9999I PSW /078D0000 AB875E26
    FPEV9999I REGS 0-1/00000000 2B2E6244
    FPEV9999I REGS 2-3/416D96DE 0000007C
    FPEV9999I REGS 4-5/416D96DE 00011CA6
    FPEV9999I REGS 6-7/423B6000 FF3236A6
    FPEV9999I REGS 8-9/423B6000 FF3236A6
    FPEV9999I REGS A-B/FFFFFFC8 29A37BC0
    FPEV9999I REGS C-D/AB875D18 2B2E6090
    FPEV9999I REGS E-F/AB856770 AB875D18
    ....................................
    ABEND S0C4-04 in FPEVDB2I module caused by timeout in DB2
    
    Forward Fit PM21646
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    *                 - Classic Interface                          *
    *                 - Performance Expert Client                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND S0C4 in FPEVDB2I.DGOVMRAS caused  *
    *                      by use of the Group option in ZALLT     *
    *                      panel of the Classic Interface.         *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Use of the Group option in ZALLT panel of the Classic Interface
    may cause ABEND S0C4 in the FPEVDB2I.DGOVMRAS section
    when DB2 returns corrupted or not complete group scope return
    area for multiple members of a data sharing group, e.g. when
    global reason code in IFCAGRSN is 00E60815 (DB2 return area
    was not large enough to hold all the data returned from other
    members).
    
    PROBLEM CONCLUSION:
    The code of PE Server subtask has been modified
    to solve this problem.
    
    KEYWORDS: S0C4 DGOVMRAS
    

Problem conclusion

  • PROBLEM CONCLUSION:
    The code of PE Server subtask has been modified
    to solve this problem.
    
    KEYWORDS: S0C4 DGOVMRAS
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM25895

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-11-04

  • Closed date

    2011-05-10

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

    PM21646

  • APAR is sysrouted TO one or more of the following:

    UK67571

Modules/Macros

  •    DGOVMRAS DGOVMSTR FPEVDB2I
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK67571

       UP11/05/11 P F105

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]