A fix is available
APAR status
Closed as program error.
Error description
KO2I0211W DAPICOMM STRUCTURE ACCESS FAILED FOR DB2 DBT1 RECOVERY SUCCESSFUL ABEND0C3 KD5ATC00+159E (at PK77333 level), this was an intentional ABEND0C3 caused when the above error was detected.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Tivoli Enterprise Monitoring Agent * **************************************************************** * PROBLEM DESCRIPTION: KD5ATC00 ABEND0C3 KO2I0211W * * DAPICOMM STRUCTURE ACCESS FAILED. * * ABEND0C4 PIC11 D5TMRXIT LOAD MODULE * * KDPAGENT at offset +A. KLV$RSS+19A * * ABEND0C6 R10 during agent shutdown. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: Re-use of storage, particularly on a multi-processor system, can cause ABEND0C3. Access of storage recently freed can cause ABEND0C4. KLV$RSS+19A ABEND0C6 R10 during agent shutdown is due to control blocks being freed by termination processing while D5API connections were being disconnected. PROBLEM CONCLUSION: Ensure storage cannot be re-used or accessed inappropriately. Ensure control blocks are not freed until D5API connections are all disconnected.
Problem conclusion
Ensure storage cannot be re-used or accessed inappropriately. Ensure control blocks are not freed until D5API connections are all disconnected. KEYWORDS : D5API ABEND0C3 KLV$RSS+19A ABEND0C6 R10 ABEND0C4
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PM25447
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-10-28
Closed date
2011-01-13
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK63805
Modules/Macros
KD5AGENT KD5ATC00 KD5AUTO1 KD5DCIF1 KD5TRM00
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UK63805
UP11/01/15 P F101
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]